Catalog 1308242
Issued 3-03
OEG
OJ/OJE series
3-10 Amp Miniature,
PC Board Relay
Appliances, HVAC, Industrial Control.
UL File No. E82292
CSA File No. LR48471
VDE File No. 10080
TUV File No. R75081
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Coil Data @ 20°C
Features
•
•
•
•
•
•
Miniature size 18.2 x 10.2 x 14.7h.
1 Form A (SPST-NO) contact arrangement.
Designed to meet UL, CSA, VDE, TUV requirements.
Designed to meet 4kV dielectric between coil and contacts (OJ).
Sensitive and standard coils available.
Immersion cleanable, sealed version available.
Contact Data @ 20°C
Arrangements: 1 Form A (SPST-NO).
Material: Ag, Ag Alloy.
Max. Switching Rate: 300 ops./min. (no load).
30 ops./min. (rated load).
Expected Mechanical Life: 10 million operations (no load).
Expected Electrical Life: 100,000 operations (rated load).
Minimum Load: 100mA @5VDC.
Initial Contact Resistance: 100 milliohms @ 1A,6VDC.
Contact Ratings
3A @ 250VAC resistive,
3A @ 28VDC resistive.
OJ/OJE-LMH: 8A @ 250VAC resistive,
8A @ 28VDC resistive.
OJ/OJE-DM: 5A @ 250VAC resistive,
5A @ 28VDC resistive.
OJ/OJE-HM: 10A @ 250VAC resistive,
10A @ 28VDC resistive.
Max. Switched Voltage: AC: 265V.
DC: 30V.
Max. Switched Power:
OJ/OJE-LM: 720VA, 90W
OJ/OJE-LMH: 1,800VA, 200W
OJ/OJE-DM: 1,200VA, 150W
OJ/OJE-HM: 2,500VA, 280W
Ratings: OJ/OJE-LM:
Note: Consult factory regarding TV-5 rated models.
Initial Dielectric Strength
Between Open Contacts:
OJ: 750VAC 50/60 Hz. (1 minute).
OJE: 750VAC 50/60 Hz. (1 minute).
Between Coil and Contacts:
OJ: 4,000VAC 50/60 Hz. (1 minute).
OJE: 3,000VAC 50/60 Hz. (1 minute).
Surge Voltage Between Coil and Contacts:
OJ: 10,000V (1.2/50µs).
OJE: 5,000V (1.2/50µs).
OJ/OJE-L Sensitive
Rated Coil
Voltage
(VDC)
Nominal
Current
(mA)
5
6
9
12
24
Coil
Resistance
(ohms) ± 10%
Must Release
Voltage
(VDC)
125
180
400
720
2,800
40.0
33.3
22.5
16.7
8.6
Must Operate
Voltage
(VDC)
3.75
4.50
6.75
9.00
18.00
0.25
0.30
0.45
0.60
1.20
OJ/OJE-D and -H Standard
Rated Coil
Voltage
(VDC)
Nominal
Current
(mA)
5
6
9
12
24
48
91.0
75.0
50.0
37.5
18.8
9.4
Coil
Resistance
(ohms) ± 10%
Must Operate
Voltage
(VDC)
Must Release
Voltage
(VDC)
55
80
180
320
1,280
5,100
3.50
4.20
6.30
8.40
16.80
33.60
0.25
0.30
0.45
0.60
1.20
2.40
Operate Data
Must Operate Voltage:
OJ/OJE -L: 75% of nominal voltage or less.
OJ/OJE -D and -H: 70% of nominal voltage or less.
Must Release Voltage:
OJ/OJE -L: 5% of nominal voltage or more.
OJ/OJE -D and -H: 5% of nominal voltage or more.
Operate Time: OJ/OJE -L: 15 ms max.
OJ/OJE -D and -H: 10 ms max.
Release Time: 4 ms max.
Environmental Data
Temperature Range:
Operating: OJ/OJE-L: -30°C to +80°C
OJ/OJE-D and -H: -30°C to +60°C.
Vibration, Mechanical: 10 to 55 Hz., 1.5mm double amplitude
Operational: 10 to 55 Hz., 1.5mm double amplitude.
Shock, Mechanical: 1,000m/s2 (100G approximately).
Operational: 100m/s2 (10G approximately).
Operating Humidity: 20 to 85% RH. (Non-condensing).
Initial Insulation Resistance
Between Mutually Insulated Elements: 1,000M ohms min. @ 500VDCM.
Coil Data
Voltage: 5 to 48VDC.
Nominal Power: OJ/OJE-LM and LMH: 200 mW.
OJ/OJE-DMand HM: 450 mW.
Coil Temperature Rise:
OJ/OJE-LM and LMH : 30°C max., at rated coil voltage.
OJ/OJE-DM and HM: 40°C max., at rated coil voltage.
Max. Coil Power: 130% of nominal.
Duty Cycle: Continuous.
Dimensions are shown for
422 reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Mechanical Data
Termination: Printed circuit terminals.
Enclosure (94V-0 Flammability Ratings):
OJ/OJE-SS: Vented (Flux-tight), plastic cover.
OJ/OJE-SH: Sealed, plastic case.
Weight: 0.32 oz (9g) approximately.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.