Dew Sensor
HDK dew sensor is a high response dew sensor to protect equipment from dew.
■Features
・Small, light
・High response and reliable dew detection
・High reliability
■Applications
・VTR
・Camera
・Copier
■Typical Characteristics
■Dimensions
HDP-07SN Type
5.2±0.2
50 or 100±0.5
HDP-07 Humidity Characteristics at25℃
(REFERENCE ONLY)
4±0.5
5.2±0.2
100000
MIN
AVG
MAX
10000
10±0.3
Unit:mm
2
4±0.2
5.2±0.2
8±0.2
Resistance Value (kΩ)
HDP-07SC Type
0.25±0.25
+0.05
Holeφ2 -0
1000
100
10
3Max.
1
0.5
Lead wire
0.1
60
Sensor substrate(Ceramic,t=0.64)
70
80
90
100
Relative Humidity (%RH)
Holder(Aluminum A5052P)
■Specifications
Item
HDP-07SN1
HDP-07SN2
Lead Length
M ounting Plate (Holder)
50
100
Unit
50
100
Yes
mm
-
AC,DC 0.8V M ax. (2mW)
V
+1~+60
0~100
℃
%RH
200kΩ M in. within 10 sec.
75%RH:20kΩ M ax., 93%RH:100kΩ M ax., 100%RH:200kΩ M in.
Ω
Working Humidity Range
Resistance(25℃)
HDP-07SC2
mm
None
Working Voltage
Working Temperature Range
Response
HDP-07SC1
5.2×5.2
Element Size
”Type”, ”Article” indicates the product No., which is not the trademark.
HOKURIKU
Specifications are subject to change without notice.
-