VDE
JC RELAYS
COMPACT POWER RELAYS
30.0
1.181
JC
FEATURES
19.0
.748
30.0
1.181
19.0
.748
30.4
1.197
32.4
1.276
PC board type
Plug-in type
19.0
.748
• High inrush current capability
1 Form A: 163 A inrush (TV-8)
2 Form A: 111 A inrush (TV-5)
• High dielectric withstanding for transient protection:
JC can withstand 10,000 V surge in µs between coil and
contact.
• Electrical life:
1 Form A: 105 ope. at 15 A 250 V AC resistive load
2 Form A: 105 ope.
at 10 A 250 V AC resistive load
• UL/CSA, VDE, TÜV, SEMKO also approved.
COMMENTS ABOUT Cd FREE
32.9
1.295
45.0
1.772
mm inch
TM type
We have introduced Cadmium free type products to reduce the
material which is not good for our environment. (The suffix “F”
should be added to the part number.) If you are still using
Cadmium containing parts, which don’t have “F” on the suffix of
the part number, please use Cadmium free parts from now on.
The life of the Cadmium free parts may be shorter than the
Cadmium containing parts based on the load condition, so
please evaluate the Cadmium free parts with your actual
application before use.
Compliance with RoHS Directive
SPECIFICATIONS
Contact
Characteristics
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Contact force, min.
Maximum switching power
Rating
Maximum switching voltage
(resistive
Max. switching current
load)
Min. switching capacity#1
Expected Mechanical
life (min.
Electrical 10 A 250 V AC
operation) (resistive) 5A 250 V AC
1 Form A
2 Form A
30 mΩ
AgSnO2 type
30 g
3,750 VA
2,500 VA
250 V AC
250 V AC
15 A
10 A
100 mA, 5 V DC
5×106
5
10
—
—
105
Coil
Nominal operating power
900 mW
1,000 mW
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement of same location as “Initial breakdown voltage” section
*2 Detection current: 10mA
*3 Excluding contact bounce time
*4 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
*6 Detection time: 10µs
*7 Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT
Maximum operating speed
Initial insulation resistance*1
Between open contacts
Initial
Between contacts sets
breakdown
Between contacts and
voltage*2
coil
20 cpm.
Min. 100 MΩ at 500 V DC
2,000 V rms for 1 min.
2,000 Vrms for 1 min.
4,000 Vrms for 1 min.
Operate time*
(at nominal voltage)
Max. 30 ms
Release time(without diode)*3
(at nominal voltage)
Max. 10 ms
Temperature rise
(at nominal voltage)
Max. 55°C
3
Shock
resistance
Vibration
resistance
Functional*
Destructive*5
4
Functional*6
Destructive
Conditions for operation,
Ambient
transport and storage*7
temp.
(Not freezing and condensHumidity
ing at low temperature)
Unit weight
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
196 m/s2 {20 G}
980 m/s2 {100 G}
98 m/s2 {10 G}, 10 to 55 Hz
at double amplitude of 1.6 mm
117.6 m/s2 {12 G}, 10 to 55 Hz
at double amplitude of 2 mm
–50°C to +60°C
–58°F to +140°F
5 to 85%R.H.
Approx. 31 g 1.09 oz