Ordering information
On-board type
ZS1R5
Z
1
S
2
1R5
3
05
4
12
5
1Series name
2Single output
3Output wattage
4Input voltage
5Output voltage
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
ZS1R50505 ZS1R50512 ZS1R50515 ZS1R51205 ZS1R51212 ZS1R51215 ZS1R52405 ZS1R52412 ZS1R52415 ZS1R54805 ZS1R54812 ZS1R54815
1.25
1.44
1.5
1.25
1.44
1.5
1.25
1.44
1.5
1.25
1.44
1.5
5V 0.25A 12V 0.12A 15V 0.1A 5V 0.25A 12V 0.12A 15V 0.1A 5V 0.25A 12V 0.12A 15V 0.1A 5V 0.25A 12V 0.12A 15V 0.1A
SPECIFICATIONS
Z
MODEL
VOLTAGE[V]
*1
CURRENT[A]
INPUT
EFFICIENCY[%]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
*2
RIPPLE[mVp-p]
OUTPUT
RIPPLE NOISE[mVp-p] *2
TEMPERATURE REGULATION[mV] 0 to +50C
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[%]
PROTECTION
OVERCURRENT PROTECTION
CIRCUIT
INPUT-OUTPUT
ISOLATION INPUT-CASE
OUTPUT-CASE
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
IMPACT
ZS1R50505 ZS1R50512 ZS1R50515 ZS1R51205 ZS1R51212 ZS1R51215 ZS1R52405 ZS1R52412 ZS1R52415 ZS1R54805 ZS1R54812 ZS1R54815
5 (4.5 - 6.0)
12 (10 - 15)
24 (20 - 30)
48 (35 - 63)
0.420typ 0.480typ 0.500typ 0.158typ 0.183typ 0.192typ 0.079typ 0.092typ 0.096typ 0.040typ 0.046typ 0.048typ
60typ
60typ
60typ
65typ
65typ
65typ
65typ
65typ
65typ
65typ
65typ
65typ
5
12
15
5
12
15
5
12
15
5
12
15
0.25
0.12
0.1
0.25
0.12
0.1
0.25
0.12
0.1
0.25
0.12
0.1
25max 60max 75max 25max 60max 75max 25max 60max 75max 25max 60max 75max
50max 120max 150max 50max 120max 150max 50max 120max 150max 50max 120max 150max
100max 120max 120max 100max 120max 120max 100max 120max 120max 100max 120max 120max
120max 120max 120max 120max 120max 120max 120max 120max 120max 120max 120max 120max
50max 120max 150max 50max 120max 150max 50max 120max 150max 50max 120max 150max
Fixed
t5max (Rated input/output, Ta=25C)
Works over 105% of rating and recovers automatically
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
-10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 30minutes each along X, Y and Z axis
490.3m/s2 (50G), 11ms, once each X, Y and Z axis
*1 Rated input 5V, 12V, 24V or 48V DC, Io=100%
*2 Measured by 20MHz oscilloscope.
* Parallel operation with other model is not possible.
G-120