S Series Data Sheet
100 Watt AC-DC and DC-DC Converters
Features
Input voltage ranges from 8 to 385 VDC and 85 to 264 VAC, 47-440 Hz
1or 2 isolated outputs up to 48 VDC
Class I equipment
• RoHS lead solder exemption compliant
• Extremely-wide input voltage range
• Input over- and undervoltage lockout
• Efficient input filter and built-in surge and transient
suppression circuitry
• Outputs: SELV, no-load, and short-circuit proof
• No derating over entire operating temperature range
• PCBs coated with protective lacquer
111
4.4"
3U
60
2.4"
12 TE
• Very high reliability
168
6.6"
Safety according to IEC/EN 60950
Description
The S Series AC-DC and DC-DC converters represents a broad
and flexible range of power supplies for use in advanced
electronic systems. Features include high efficiency, high
reliability, low output voltage noise and excellent dynamic
response to load/line changes. LS models can be powered by
DC or AC with a wide-input frequency range (without PFC).
The converter inputs are protected against surges and
transients. An input over- and undervoltage lockout circuitry
disables the outputs if the input voltage is outside of the
specified range. Certain types include an inrush current limiter
preventing circuit breakers and fuses from tripping at switch-on.
All outputs are open- and short-circuit proof and are protected
against overvoltages by means of built-in suppressor diodes.
The outputs can be inhibited by a logic signal applied to pin 18
(i). If the inhibit function is not used, pin 18 must be connected
with pin 14 to enable the outputs.
LED indicators display the status of the converter and allow for
visual monitoring of the system at any time.
The case design allows operation at nominal load up to 71 °C in a
free-air ambient temperature. If forced cooling is provided, the
ambient temperature may exceed 71 °C, but the case temperature
must remain below 95 °C under all conditions.
A temperature sensor generates an inhibit signal, which disables
the outputs if the case temperature Tc exceeds the limit. The
outputs are automatically re-enabled when the temperature drops
below the limit.
Various options are available to adapt the converters to individual
applications.
The converters may either be plugged into a 19" rack system
according to IEC 60297-3, or be chassis mounted. They are ideally
suited for Railway applications.
Important: For applications requiring compliance with IEC/EN
61000-3-2 (harmonic distortion), please use our LS4000 and LS5000
Series with incorporated power factor correction (PFC).
Full input-to-output, input-to-case, output-to-case and output-tooutput isolation is provided. The converters are designed and
built according to the international safety standards IEC/EN
60950 and EN50155. They have been approved by the safety
agencies TÜV and UL (for USA and Canada).
Table of Contents
Page
Page
Description ................................................................................1
Model Selection ........................................................................2
Part Number Description and Product Marking ........................3
Functional Description ..............................................................4
Electrical Input Data ..................................................................5
Electrical Output Data ..............................................................8
Auxiliary Functions ..................................................................12
Electromagnetic Compatibility (EMC) ....................................15
Immunity to Environmental Conditions ..................................17
Mechanical Data ....................................................................18
Safety and Installation Instructions ........................................19
Description of Options ............................................................23
Accessories ............................................................................32
EC-Declaration of Conformity ................................................33
APR 26, 2006 revised to SEP 25, 2006
Page 1 of 33
www.power-one.com
S Series Data Sheet
100 Watt AC-DC and DC-DC Converters
Part Number Description and Product Marking
C S 2 5 40 -9 E R
D3 T B1
Input voltage range Vi:
8 - 35
14 - 70
20 - 100
28 - 140
44 - 220
67 - 385
85 - 264 VAC or 88 - 372
VDC ................A
VDC .............. B
VDC .............. F
VDC ................C
VDC ................D
VDC .............. E
VDC................ L
Series................................................................................S
Number of outputs ........................................................1, 2
Single output models:
Nominal voltage output 1 (main output), Vo1 nom
5.1 V ......0, 1, 2
12 V ................3
15 V ............4, 5
24 V ................6
1
Other voltages ............7, 8
Other specifications for
1
single output models ......01 - 99
Double output models:
Nominal voltage output 1 and 2
12, 12V ......................................................................20
15, 15V ......................................................................40
24, 24V ......................................................................60
1
Other specifications and additional features ......70 - 99
Operational ambient temperature range TA:
–25 to 71 °C................-7
–40 to 71 °C................-9
Other 1 ....-0, -5, -6
Auxiliary functions and options:
Inrush current limiter ......................................................E 3
Output voltage control input ..........................................R 2
Potentiometer (output voltage adjustment) ....................P 2
Undervoltage monitor (D0 - DD, to be specified) ..........D 4
ACFAIL signal (V0, V2, V3, to be specified) ..................V 4
Current share ....................................................................T
Cooling plate standard case ..........................................B1
Cooling plate for long case (220 mm) 1 ..........................B2
1
Customer-specific models.
2
Feature R excludes option P and vice versa.
3
Option E available for CS, DS, ES, FS, and LS models; mandatory for all -9 model types.
4
Option D excludes option V and vice versa; option V available for S1001 models only.
Example:
CS2540-9ERD3TB1: DC-DC converter, input voltage range 28 - 140 V, double output, each providing 15 V/3.2 A,
equipped with inrush current limiter, R input (voltage adjust), undervoltage monitor D3, current share, and a cooling plate
B1. Ambient temperature –40 to 71 °C.
Product Marking
Basic type designation, applicable approval marks, CE mark, warnings, pin allocation, Power-One patents, and company logo.
Identification of LEDs, test sockets, and potentiometer.
Specific type designation, input voltage range, nominal output voltages and currents, degree of protection, batch no., serial no., and
data code including production site, modification status, and date of production.
APR 26, 2006 revised to SEP 25, 2006
Page 3 of 33
www.power-one.com