COST SAVING
SUBMINIATURE
PC BOARD RELAYS
14.0
.551
14.2
.559
26.5
1.043
26.3
1.035
16.9
.665
17.7
.697
HA-RELAYS
FEATURES
• Compact construction
• Sensitive - very low operating power
• Soldering flux inflow prevented by molded construction
• Contact capacity - 3 A 250 V AC, 30 V DC
• Simple mechanism for stable quality - only 9 pieceparts
• Amber sealed types available
HAE Amber Relays
mm inch
SPECIFICATIONS
HA1 Standard type
Contacts
HA1E Amber sealed type
Contacts
Arrangement
1 Form C
Contact material
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Max. switching power
Rating
(resistive
Max. switching voltage
load)
Max. switching current
Mechanical
Expected
life (min.
Electrical 3 A 250 V AC
operations) (resistive) 3 A 30 V DC
Silver-nickel
50 mΩ
750 VA, 90 W
250 V AC, 30 V DC
3A
107
105
5×105
Coil
(AC) 0.58 VA, (DC) 230 mW
(AC) 0.9 VA, (DC) 360 mW
Characteristics
Operate time*3 (at nominal voltage)
(at 20°C)
Release time (without diode)*3
(at nominal voltage)(at 20°C)
Temperature rise (at 20°C)
Functional
Destructive
Functional
Vibration resistance
Destructive
20 cpm
Min. 100 MΩ at 500 V DC
750 Vrms for 1 min.
1,500 Vrms for 1 min.
Approx. 6 ms (AC),
Approx. 5 ms (DC)
Approx. 6 ms (AC),
Approx. 3 ms (DC)
Max. (AC) 60°C, (DC) 40°C
with nominal coil voltage and
at 3A switching current
98 m/s2 {10G}
980 m/s2 {100G}
10 to 55Hz
at double amplitude of 1mm
10 to 55Hz
at switching of 2mm
Ambient
temp.
–40°C to +50°C
–40°F to +122°F
Humidity
5 to 85%R.H.
Approx. 15 g .53 oz
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Intial breakdown voltage" section
*2 Detection current: 10 mA
208
50 mΩ
500 VA, 90 W
250 V AC, 30 V DC
2 A AC, 3A DC
107
105
2×105
Minimum operating power
Nominal operating power
(AC) 0.58 VA, (DC) 230 mW
(AC) 0.9 VA, (DC) 360 mW
Characteristics
Maximum operating speed
Initial insulation resistance*1
(at 25°C, 50% R.H.)
Initial
Between open contacts
breakdown
2
Between contacts and coil
voltage*
Conditions for operation,
transport and storage*4
(Not freezing and condensing at low temperature)
Unit weight
Remarks
1 Form C
Gold-clad over silver-nickel
Coil
Minimum operating power
Nominal operating power
Shock resistance
Arrangement
Contact material
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Max. switching power
Rating
(resistive
Max. switching voltage
load)
Max. switching current
Mechanical
Expected
life (min.
Electrical 2 A 250 V AC
operations) (resistive) 3 A 30 V DC
Maximum operating speed
Initial insulation resistance*1
(at 25°C, 50% R.H.)
Initial
Between open contacts
breakdown
2
Between contacts and coil
voltage*
Operate time*3 (at nominal voltage)
(at 20°C)
Release time (without diode)*3
(at nominal voltage)(at 20°C)
Temperature rise (at 50°C)
Shock resistance
Functional
Destructive
Functional
Vibration resistance
Destructive
Conditions for operation,
transport and storage*4
(Not freezing and condensing at low temperature)
Unit weight
20 cpm
Min. 100 MΩ at 500 V DC
750 Vrms for 1 min.
1,500 Vrms for 1 min.
Approx. 6 ms (AC),
Approx. 5 ms (DC)
Approx. 6 ms (AC),
Approx. 3 ms (DC)
Max. (AC) 60°C, (DC) 40°C
with nominal coil voltage and
at 3A switching current
98 m/s2 {10G}
980 m/s2 {100G}
10 to 55Hz
at double amplitude of 1mm
10 to 55Hz
at double amplitude of 2mm
Ambient
temp.
–40°C to +50°C
–40°F to +122°F
Humidity
5 to 85%R.H.
Approx. 15 g.53 oz
*3 Excluding contact bounce time
*4 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).