IS42S81600E
IS42S16800E
16M x 8, 8M x16
128Mb SYNCHRONOUS DRAM
APRIL 2011
OVERVIEW
ISSI's 128Mb Synchronous DRAM achieves high-speed
FEATURES
• Clock frequency: 200, 166, 143, 133 MHz
• Fully synchronous; all signals referenced to a
positive clock edge
data transfer using pipeline architecture. All inputs and
outputs signals refer to the rising edge of the clock input.
The 128Mb SDRAM is organized as follows.
• Internal bank for hiding row access/precharge
• Power supply
IS42S81600E
Vdd Vddq
3.3V 3.3V
IS42S16800E
3.3V 3.3V
IS42S81600E
IS42S16800E
4M x8 x4 Banks
2M x16 x4 Banks
54-pin TSOPII
54-pin TSOPII
• LVTTL interface
54-ball TF-BGA
• Programmable burst length
– (1, 2, 4, 8, full page)
• Programmable burst sequence:
Sequential/Interleave
• Auto Refresh (CBR)
• Self Refresh
• 4096 refresh cycles every 64 ms
• Random column address every clock cycle
• Programmable CAS latency (2, 3 clocks)
• Burst read/write and burst read/single write
operations capability
• Burst termination by burst stop and precharge
command
• Industrial Temperature Availability
KEY TIMING PARAMETERS
Parameter
Clk Cycle Time
CAS Latency = 3
CAS Latency = 2
Clk Frequency
CAS Latency = 3
CAS Latency = 2
Access Time from Clock
CAS Latency = 3
CAS Latency = 2
-5
5
10
200
100
5.0
6.5
-6
6
10
166
100
5.4
6.5
-7
7
10
143
100
5.4
6.5
-75E Unit
—
ns
7.5
ns
—
Mhz
133 Mhz
—
ns
5.4
ns
Copyright © 2011 Integrated Silicon Solution, Inc. All rights reserved. ISSI reserves the right to make changes to this specification and its products at any time without notice. ISSI assumes no liability arising out of the application or use of any information, products or services described herein. Customers are advised to obtain
the latest version of this device specification before relying on any published information and before placing orders for products.
Integrated Silicon Solution, Inc. does not recommend the use of any of its products in life support applications where the failure or malfunction of the product can
reasonably be expected to cause failure of the life support system or to significantly affect its safety or effectiveness. Products are not authorized for use in such applications unless Integrated Silicon Solution, Inc. receives written assurance to its satisfaction, that:
a.) the risk of injury or damage has been minimized;
b.) the user assume all such risks; and
c.) potential liability of Integrated Silicon Solution, Inc is adequately protected under the circumstances
Integrated Silicon Solution, Inc. — www.issi.com
Rev. D
03/16/2011
1