Ordering information
On-board type
YS5
Y
1
S
2
5
3
05A
4
1Series name
2Single output
3Output wattage
4Output voltage
R
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
YS505A
5.0
5V 1.0A
YS512A
5.4
12V 0.45A
YS505A
AC85 - 132 1f or DC110 - 170
0.15typ (Io=100%)
47 - 440 or DC
68typ (Io=100%)
15typ (Io=100%)
YS512A
SPECIFICATIONS
INPUT
OUTPUT
Y
PROTECTION
CIRCUIT
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
MODEL
VOLTAGE[V]
ACIN 100V
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%] ACIN 100V
INRUSH CURRENT[A] ACIN 100V
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
*1
RIPPLE[mVp-p]
RIPPLE NOISE[mVp-p] *1
TEMPERATURE REGULATION[mV] 0 to +55C
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[%]
HOLD-UP TIME[ms]
OVERCURRENT PROTECTION
INPUT-FG, OUTPUT
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
5
12
1
0.45
20max
48max
40max
100max
80max
120max
120max
150max
50max
150max
200max (ACIN 85V, Io=100%)
Fixed
t5max (Rated input/output, Ta=25 C)
10typ (ACIN 85V, Io=100%)
Works over 105% of rating and recovers automatically
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
-10 to +70C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 98.0m/s2 (10G), 3minutes period, 30minutes each along X, Y and Z axis
490.3m/s2 (50G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL
Complies with FCC-B
*1 Measured by 20MHz oscilloscope.
* Parallel operation with other model is not possible.
G-178
70typ (Io=100%)