FD400
ENGINEERING DATA SHEET
RELAY - NONLATCH
2 PDT, 10 AMP/56VDC
Polarized, non latching hermetically sealed relay
Contact arrangement
2 PDT NC - NO (DB - DM)
Coil supply
Direct current
PRINCIPLE TECHNICAL CHARACTERISTICS
Contacts rated at
10 Amps / 56 Vdc
Weight
80 grams max
Dimensions of case
26mm x 25.7mm x 26mm max
Hermetically sealed, corrosion protected metal can.
Intrinsically safe relay.
APPLICATION NOTES:
001
002
007
APPLICABLE SOCKET:
SFD400CE40E
CONTACT ELECTRICAL CHARACTERISTICS
Minimum
operating cycles
100,000 cycles
20,000 cycles
50 cycles
400,000 cycles
Contact rating per
pole and load type
Load Current in Amps
@56Vdc
resistive load
inductive load (L/R=5ms)
10
6
resistive overload
40
at 25% rated resistive load
LEACH ® INTERNATIONAL
North America
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622 USA
Europe, SA
2 Rue Goethe
57430 Sarralbe
France
Asia-Pacific Ltd.
20/F Shing Hing Commercial Bldg.
21-27 Wing Kut Street
Central, Hong Kong
www.leachintl.com
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
Tel: (33) 3 87 97 98 97
Fax: (33) 3 87 97 84 04
Tel: (852) 2 191 2886
Fax: (852) 2 389 5803
Solutions for Power Switching and Control
Date of issue: 6/00
- 101 -