Ordering information
On-board type
ZUW15
ZU
1
W
2
15
3
12
4
DC OUTPUT
ZUW150512
14.4
VOLTAGE[V] t12 or +24
CURRENT[A] 0.6
SPECIFICATIONS
ZU/ZT
MODEL
VOLTAGE[V]
*1
INPUT
CURRENT[A]
*1
EFFICIENCY[%]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
*2
RIPPLE[mVp-p]
RIPPLE NOISE[mVp-p] *2
OUTPUT
TEMPERATURE REGULATION[mV] 0 to +55C
*3
DRIFT[mV]
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
PROTECTION OVERVOLTAGE PROTECTION
CIRCUIT
REMOTE ON/OFF
INPUT-OUTPUT
ISOLATION INPUT-CASE
OUTPUT-CASE
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
IMPACT
SAFETY
AGENCY APPROVALS
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
*1
*2
*3
*
*
ZUW150515
15.0
t15 or +30
0.5
ZUW151212
15.6
t12 or +24
0.65
ZUW151215
15.0
t15 or +30
0.5
ZUW152412
15.6
t12 or +24
0.65
ZUW152415
15.0
t15 or +30
0.5
ZUW154812
15.6
t12 or +24
0.65
ZUW154815
15.0
t15 or +30
0.5
Output pins can be connected in series to make a 24V/30V output.
ZUW150512 ZUW150515 ZUW151212 ZUW151215 ZUW152412 ZUW152415 ZUW154812 ZUW154815
DC4.5 - 9
DC9 - 18
DC18 - 36
DC36 - 75
3.56typ
3.70typ
1.57typ
1.51typ
0.78typ
0.75typ
0.39typ
0.38typ
81typ
81typ
83typ
83typ
83typ
83typ
83typ
83typ
t12 (+24) t15 (+30) t12 (+24) t15 (+30) t12 (+24) t15 (+30) t12 (+24) t15 (+30)
0.60
0.50
0.65
0.50
0.65
0.50
0.65
0.50
60max
75max
60max
75max
60max
75max
60max
75max
600max
750max
600max
750max
600max
750max
600max
750max
120max
120max
120max
120max
120max
120max
120max
120max
150max
150max
150max
150max
150max
150max
150max
150max
150max
180max
150max
180max
150max
180max
150max
180max
50max
60max
50max
60max
50max
60max
50max
60max
100max (Minimum input, Io=100%)
Internally fixed (TRM pin open),t5% adjustable by external VR
11.40 - 12.60 14.25 - 15.75 11.40 - 12.60 14.25 - 15.75 11.40 - 12.60 14.25 - 15.75 11.40 - 12.60 14.25 - 15.75
Works over 105% of rating and recovers automatically
Works at 115 - 140% of rating (Total of +V and -V)
Between RC and -side of input:short - 1.2V ---output ON, 2.4V - 5.5V(or open)---output OFF, Compatible to TTL
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
-20 to +71C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-40 to +85C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 98.0m/s2 (10G), 3minutes period, 60minutes each along X, Y and Z axis
490.3m/s2 (50G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, CSA C22.2 No.60950-1 Complies with IEC60950-1
45X8.5X50mm (WXHXD) / 55g max
Convection
Rated input 5V, 12V, 24V or 48V DC, Io=100%.
Measured by 20MHz oscilloscope.
The drift is a change at 25C of ambient temperature and 30 minutes - 8 hours after the input voltage applied at rated input/output.
The output specification is at t12V and t15V.
Series/Parallel operation with other model is not possible.
G-116
5
1Series name
2Dual output
3Output wattage
4Input voltage
5Output voltage
R
MODEL
MAX OUTPUT WATTAGE[W]
12