Slot-type Photomicrosensor (Non-modulated) *1
EE-SX47/67
CSM_EE-SX47/67_DS_E_11_2
Global Standard Slot-type
photomicrosensors with 50- to
100-mA direct switching capacity.
• Series includes models that enable switching between
dark-ON and light-ON operation.
• Response frequency as high as 1 kHz.
• Easy operation monitoring with bright light indicator.
• Wide operating voltage range: 5 to 24 VDC
• Models in which the light indicator turns ON for dark-ON
operation are also available.
• A wide range of variations in eight different shapes.
• Flexible robot cable is provided as a standard feature. *2
Be sure to read Safety Precautions on
page 5.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
*1. Pre-wired Models are available only in the EE-SX67 Series.
*2. Only for Pre-wired Models.
Ordering Information
Connector
Appearance
Infrared light
Sensing Connectmethod ing method
Sensing distance
Output
configuration
Indicator mode
Model
NPN output
PNP output
Dark-ON/Light-ON Incident light
(selectable) *3 *4 No incident light
L-shaped
EE-SX670
EE-SX670P
EE-SX670A
EE-SX670R
Light-ON
Standard
EE-SX470
Incident light
---
Dark-ON/Light-ON Incident light
(selectable) *3 *4 No incident light
EE-SX672P
EE-SX672A
EE-SX672R
EE-SX472
---
EE-SX673
EE-SX673P
EE-SX673A
EE-SX673R
Light-ON
EE-SX473
---
Dark-ON/Light-ON Incident light
(selectable) *3 *4 No incident light
EE-SX674
EE-SX674P
EE-SX674A
EE-SX674R
Incident light
EE-SX474
---
Dark-ON/Light-ON
Incident light
(selectable) *3 *4
EE-SX675
EE-SX675P
Dark-ON/Light-ON
Incident light
(selectable) *3 *4
EE-SX676
EE-SX676P
Dark-ON/Light-ON
Incident light
(selectable) *3 *4
T-shaped,
slot center
10 mm
(slot width)
EE-SX672
Light-ON
Closemounting
5 mm
---
Dark-ON/Light-ON Incident light
(selectable) *3 *4 No incident light
Connector
(4 poles)
EE-SX471
Dark-ON/Light-ON Incident light
(selectable) *3 *4 No incident light
Throughbeam
type
(with slot)
EE-SX671R
Light-ON
Closemounting
EE-SX671P
EE-SX671A
Light-ON
T-shaped,
slot center
7 mm
EE-SX671
EE-SX677
EE-SX677P
Incident light
Incident light
Incident light
F-shaped
R-shaped
*3. Dark-ON when the L terminal of the connector is opened, and light-ON when the L terminal and positive (+) terminal are connected. Do not connect the L terminal
to 0 V when using dark-ON operation. When using light-ON, it is useful to select the connector EE-1001-1. The L terminal and positive (+) terminal of this connector
are connected in advance.
*4. If you do not use the L terminal wire ((2) pink) when you use a Connector with Cable for an EE-1006 or EE-1010-series Photomicrosensor, noise may affect the
Photomicrosensor. To prevent the effects of noise, cut the unused L terminal wire at the base of the connector and wrap it with insulating tape to prevent it from
coming in contact with other terminals.
1