部品型式

LEP240F-24

製品説明
仕様・特性

AC-DC Power Supplies Open Frame/ Enclosed type Ordering information LEP240F LEP 240 1 2 F 3 -24 4 Recommended EMI/EMC Filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series LEP *The EMI/EMC Filter is recommended *to connect with several devices. MODEL DC OUTPUT LEP240F-24 +24V 10(Peak 20)A LEP240F-36 +36V 6.7(Peak 13.4)A -O 5 1Series name 2Output wattage 3Universal input 4Output voltage 5Optional *1 *6 G :Low leakage current R :with Remote ON/OFF S :with Chassis SN:with Chassis & cover T :Vertical terminal block U :Operating stop voltage is set at a lower value Z :with ZT LEP240F-48 +48V 5(Peak 10)A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 200V FREQUENCY[Hz] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS ACIN 100V ACIN 200V ACIN 100V POWER FACTOR ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] *2 WATTAGE[W] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +40C *3 RIPPLE[mVp-p] -10 - 0C *3 0 to +40C *3 RIPPLE NOISE[mVp-p] -10 - 0C *3 0 to +40C TEMPERATURE REGULATION[mV] -10 to +40C DRIFT[mV] *4 START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION REMOTE ON/OFF INPUT-OUTPUT -RC *5 INPUT-FG OUTPUT-RC-FG *5 OUTPUT-RC *5 OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD EFFICIENCY[%] LEP240F-24 LEP240F-36 LEP240F-48 AC85 - 264 1f or DC 120 - 370 3.3typ (Io=100%) 1.7typ (Io=100%) 50/60 (47 - 63) or DC 83typ (Io=100%) 84typ (Io=100%) 84typ (Io=100%) 86typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 0.98typ (Io=100%) 0.93typ (Io=100%) 15typ (Io=100%) (More than 3sec.to re-start) 30typ (Io=100%) (More than 3sec.to re-start) 0.75max (60Hz, According to IEC60950 and DEN-AN) +24 +36 +48 0 - 10 (Peak 20) 0 - 6.7 (Peak 13.4) 0 - 5 (Peak 10) 240.0 (Peak 480) 241.2 (Peak 482.4) 240.0 (Peak 480) 48max 48max 48max 76max 90max 150max 120max 120max 150max 160max 160max 300max 150max 150max 250max 180max 180max 350max 120max 150max 240max 145max 180max 300max 48max 48max 48max 500max (ACIN 100V, Io=100%) 20typ (ACIN 100V, Io=100%) 21.4 - 26.4 26.4 - 39.6 39.6 - 52.8 23.0 - 25.0 35.0 - 37.0 46.0 - 50.0 Works over 101% of peak current and recovers automatically Works at 115 - 140% of rating Option (Refer to Instruction Manual) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature) -10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL(CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input) Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B Complies with IEC61000-3-2 *7 95X45X222mm [3.74X1.77X8.74 inches] (WXHXD) /690g max (with chassis & cover : 1,070g max) Convection *1 Specification is changed at option, refer to Instruction Manual 6. *2 Peak loading for 10sec. And Duty 35% max, refer to Instruction Manual 5. In detail. *3 This is the value that measured on measuring board with capacitor of 22mF within 150mm from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM101). *4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. LEP-6 *5 *6 *7 * * * Applicable when remote control (optional) is added. Please contact us about safety approvals for the model with option. Please contact us about class C. Parallel operation with other model is not possible. Derating is required when operated with chassis and cover. A sound may occur from power supply at peak loading.

ブランド

COS

供給状況

 
Not pic File
お求め部品LEP240F-24は、弊社営業STAFFが在庫確認を行いemailにて見積回答致します。

「見積依頼」ボタンを押してお気軽にお問合せ下さい。

送料

お買い上げ小計が1万円以上の場合は送料はサービスさせて頂きます。
1万円未満の場合、また時間指定便はお客様負担となります。
(送料は地域により異なります。)


お取引内容はこちら
LEP240F-24の取扱い販売会社 株式会社クレバーテック  会社情報(PDF)    戻る


0.0602619648