Data Sheet
100VAC Input/12VDC (350mA) Output
Isolated AC/DC Converter
BP5710-1
Absolute Maximum Ratings
Dimensions (Unit : mm)
Unit
V
mApk
kV
°C
°C
Vrms
Typ.
141
12.0
−
0.15
0.15
0.25
77
−
Max.
162
13.0
350
0.3
0.3
−
−
−
Mark Side
2
4
5
8
10 1 1
0.5±0.1
P= 2.54±0.2
2s
Electrical Characteristics
Symbol Min.
Parameter
Input voltage range
120
Vi
Output voltage
Vo
11.0
Output current
Io
0
Line regulation
Vr
−
Load regulation
Vl
−
Output ripple voltage
Vp
−
Power conversion efficiency
η
70
Isolation resistance
BR
100
1
4±1.0
IEC61000-4-2 Highest level 1
24.0MAX.
DC
15.0MAX.
36.0MAX.
Conditions
DC(85 to 115VAC)
Vi=141V, Io=350mA
∗1
Vi=141V
Vi=120 to 162V, Io=350mA
Vi=141V, Io=0 to 350mA ∗2
Vi=141V, Io=350mA
∗2
Vi=141V, Io=350mA
DC100V between 1&2 order
Unit
V
V
mA
V
V
Vp-p
%
MΩ
∗1 The max Output current is changed due to the ambient temperature. Please refer to the note regarding derating curve.
∗2 Please refer to regarding the definitions of the Load regulation, Conversion efficiency.
0 . 2 5 ±0 . 0 5
1.3±0.2
5.5MAX
2.54�10=25.4
5.25MAX.
9.75MAX.
Derating Curve
Derating Curve
400
350
300
250
200
Operation Range
150
100
50
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
Output Current Io(mA)
170
350
2
−20 to +80
−25 to +105
1800
Conditions
Switching Frequency
Switching Frequency fsw(kHz)
Limits
Parameter
Symbol
Input voltage
Vi
Output current
Io
ESD endurance
Vsurge
Operating temperature range
Topr
Storage temperature range
Tstg
Voltage between 1&2 order
BV
Switching Frequency
(Ta=25°C, Vi=141V)
600
500
Application Circuit
400
300
1 2
FL1
8
10 11
Output
12V
FUSE
D1
Input
AC100V
50Hz/60Hz
4 5
+
−
ZNR C1
C2
+
−
C3
C4
C5
Please verify operation and characteristics in the customer's circuit before actual usage.
Ensure that the load current does not exceed the maximum rating.
External Component Specifications
100
0
0
A varistor is required to protect against lightning surges and static electricity.
In the absolute maximum ratings, the reverse peak voltage should be
400V or higher, the average rectifying current should be 0.5A or higher,
and the peak surge current should be 20A or higher.
(Full-wave rectification can be used.)
Conversion Efficiency
100
90
80
70
60
50
40
30
20
10
0
0
Rated voltage : 200V or higher. Capacitance : 33 to 330µF
FL1: Noise reduction filter
50 100 150 200 250 300 350
Output Current Io(mA)
C1,2,4 : Noise reduction
capacitors
Capacitance (C1,C2) : 0.1 to 0.22µF, (C4) : 4700pF
Rated voltage : 200V or higher. Film or ceramic capacitor.
Evaluate under actual operating conditions.
Load Regulation
(Ta=25°C, Vi=141V)
12
10
8
6
4
2
Use a line filter if necessary.
Capacitance : 470 to 1000µF Rated voltage : 25V or higher,
ESR is 0.16Ω max. Ripple current is 0.58Arms or greater
Low impedance type.
Evaluate under actual operating conditions.
www.rohm.com
©2010 ROHM Co., Ltd. All rights reserved.
Conversion Efficiency
(Ta=25°C, Vi=141V)
14
1/1
0
0
100 200 300 400 500 600 700
Output Current Io(mA)
Surface Temperature Increase
Surface Temperature Rising ∆T(°C)
C3: Input smoothing
capacitor
C5: Output smoothing
capacitor
50 100 150 200 250 300 350
Output Current Io(mA)
Load Regulation
FUSE : Use a quick-acting fuse of 0.5A.
ZNR : Varistor
D1: Rectifier diode
200
Conversion Efficiency η(%)
Be sure to use fuse for safety.
Function
Input terminal Vi(141VDC)
Input terminal Vi(141VDC)
Not used
COMMON (Primary)
COMMON (Primary)
Not used
Not used
COMMON (Secondary)
Not used
Capacitor connect
Output terminal Vo(12V)
Output Voltage Vo(V)
BP5710-1
Pin No.
1
2
3
4
5
6
7
8
9
10
11
60
Surface Temperature Increase
(Ta=25°C, Vi=141V)
50
40
30
20
10
0
0
50
100 150 200 250 300 350
Output Current Io(mA)
2010.01 - Rev.A