Technical data
Rated voltage
440 VAC 50/60 Hz (ENEC)
480 VAC 50/60 Hz (UL, CSA)
Capacitance range
0.1 – 2.2 µF
Capacitance tolerance
± 20% standard, ± 10% option
Temperature range
–40 to +105°C
Climatic category
40/105/56/B
l
b
p
d
22.5 ± 0.4
27.5 ± 0.4
37.5 ± 0.5
std l
max l b
0.8 6 30
0.8 6 30
1.0 6 30
±0.4
±0.4
±0.7
Tolerance in lead length
+0
< 30 mm –1 mm
Approvals
ENEC, UL, cUL
Dissipation factor
Maximum values at +23°C
C ≤ 0.1 µF 0.1µF < C ≤ 1 µF
1 kHz
0.1%
0.1%
10 kHz
0.2%
0.4%
100 kHz
0.6%
–
30 mm
+5
–0
mm
C > 1 µF
0.1%
0.8%
–
Test voltage between
terminals
The 100% screening factory test is carried out at 3000
VDC. The voltage level is selected to meet the
requirements in applicable equipment standards. All
electrical characteristics are checked after the test.
Resonance frequency
Tabulated self-resonance frequencies f0 refer to 5 mm
lead length.
Insulation resistance
C ≤ 0.33 µF: ≥ 30 000 MΩ
C > 0.33 µF: ≥ 10 000 s
In DC application
Recommended voltage: ≤1000VDC
Environmental test data
Endurance
EN/IEC 60384-14:2005
1.25 x UR VAC 50 Hz,
once every hour increased
to 1000 VAC for 0.1 s,
1000 h at upper rated temperature
Vibration
IEC 60068–2–6
Test Fc
3 directions at 2 hours each,
10–55 Hz at 0.75 mm or 98 m/s2
No visible damage
No open or short circuit
Bump
IEC 60068–2–29
Test Eb
1000 bumps at
390 m/s2
No visible damage
No open or short circuit
Change of temperature
IEC 60068–2–14
Test Na
Upper and lower rated
temperature 5 cycles
No visible damage
Active flammability
EN/IEC 60384-14:2005
Passive flammability
EN/IEC 60384-14:2005
UL1414
Enclosure material of
UL94V–0 flammability class
Humidity
IEC 60068-2-3
Test Ca
+40°C and
90 – 95% R.H.
56 days