ZWS-PAF Series
150W to 480W Single Output Power Supplies
Features
Universal Input (85 - 265VAC)
Power factor Corrected
200% Peak Power capability
2 year warranty
Less than 0.5mA earth leakage current
Input Transient Protected
Key Market Segments & Applications
Specifications
Model
Input Voltage
Input Current (Forced air (1)
Inrush Current
(1,2)
Power Factor
Leakage Current
Temperature Coefficient
Overcurrent Protection
(3)
Overvoltage Protection
Hold Up Time (Typ) at 100VAC
Efficiency
Remote On/Off
Line Regulation
Load Regulation
Ripple & Noise
Operating Temperature
(4)
Operating Temperature
(4)
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
A
A
mA
V
ms
%
%
%
%
°C
°C
°C
-
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated EMI
Recommended EMI Filter
Immunity
Weight (Typ)
Size (WxHxD)
Warranty
g
mm
yrs
ZWS150PAF
ZWS240PAF
85-265VAC (47-63Hz), 120-370VDC
2.8/1.4
4.0/2.0
14 / 28
0.99 at 100VAC, 0.95 at 200VAC, Meets EN61000-3-2
0.5mA Max. Typically 0.1mA (100VAC), 0.22mA (230VAC)
<0.02%/°C
>102% of peak current capability
24V: 30-35V, 36V: 43.2-50.4, 48V: 55.2-64.8V
20 (16ms at forced air power ratings)
82
See installation manual (Not available with /A cover option)
0.4%
0.8%
1%
(Open frame or L bracket) -10°C to +70°C, derate linearly to 70% load from 60°C to 70°C
(With /A cover option) -10°C to +60°C, derate linearly to 70% load from 50°C to 60°C
-30 to +85°C
Operating: 30 - 90% RH, Operating: 10 - 95% RH
Convection or Forced Air Cooled (1.5m/s)
Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA),
Output to Ground 500VAC (100mA) for 1 min.
>100M at 25°C & 70% RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
< 196.1 m/s2
UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark
EN55022/EN55022-B, FCC Class B, VCCI-B
RSEL-2006W
EN61000-4-2, -3, -4, -5, -6, -8, -11
500g (800g with cover)
750g (1100g with cover)
See Outline Drawings
Two Years
Notes:
(1) 100/200VAC
(2) 25°C ambient (cold start)
(3) Avoid prolonged operartion in overload
(4) With 0.7m/s airflow. See derating table for convection cooling
1-800-526-2324 • www.us.tdk-lambda.com/lp/
176
Disclaimer: us.tdk-lambda.com/lp/legal.htm