DS
High Reliability Relay for
Various Applications
DS RELAYS
FEATURES
1. Breakthrough height of 9.8 mm .386
inch beats the 10 mm .394 inch limit
1c and 2c all have the same height
(9.8 mm .386 inch). The width of the
relay is also the same (9.9 mm .390
inch). Since the only size variable is
the length, the shared form makes
mounting on printed printing wiring
boards easy.
2. Suitable for use in difficult
environments
Epoxy resin seals the parts and cut off
the external atmosphere, thus enabling
use in difficult environments.
3. Can be used with automatic solder
and automatic wash systems
Automatic soldering and automatic
washing can be carried out once the
parts are mounted on PC boards.
4. Gold-clad twin contacts ensure high
reliability
Highly stable gold cladding on the
contacts ensures that contact
resistance changes little over time.
Furthermore, the use of twin contacts,
a configuration that performs with
superior contact reliability, ensures
extremely low contact failure rates
even under low level loads.
5. Polarized magnetic circuits realize
resistance to shock and vibration
High-performance polarized magnetic
circuits that utilize the energy of
permanent magnets have made it
possible to create relays with strong
resistance to shock and vibration.
6. DIL terminal array enables use of IC
sockets
7. Widening scope of application with
multicontact latching
In addition to single side stable types,
you can take advantage of the memory
of functions of convenient 1 coil or 2
coil latching relays.
8. Sealed according to RTIII (IP67)
TYPICAL APPLICATIONS
Besides telecommunications, measuring
devices, office equipment, computers
and related equipment, DS relays are
also recommended for a broad range of
applications including business devices,
audio systems, and industrial equipment.
ORDERING INFORMATION
DS
E
Contact arrangement
1: 1 Form C
2: 2 Form C
Sensitivity
S: 200 mW nominal operating power
Operating function
Nil: Single side stable
L2: 2 coil latching
Nominal coil voltage
DC 1.5, 3, 5, 6, 9, 12, 24, 48 V
Notes: * Nominal coil voltage 1.5V types are 1 Form C only.
ds_61005_en_ds: 280114D
1
DS
2. Specifications
Characteristics
Contact
Rating
Item
Arrangement
Initial contact resistance, max.
Contact material
Nominal switching capacity
Max. switching power
Max. switching voltage
Max. carrying current
Min. switching capacity (Reference value)*1
Nominal operating power
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Electrical
characteristics
Between open contacts
Between contact and coil
Temperature rise
Operate time [Set time] (at 20C 68F)
Release time [Reset time] (at 20C 68F)
Functional*2
Destructive
Functional
Vibration resistance
Destructive
Mechanical
Electrical
Shock resistance
Mechanical
characteristics
Expected life
Conditions for operation, transport and storage*3
Conditions
Max. operating speed (at rated load)
Unit weight
Specifications
1 Form C
2 Form C
Max. 50 m (By voltage drop 6 V DC 1A)
Ag+Au clad
2 A 30 V DC (resistive load)
60 W, 125 VA (resistive load)
220 V DC, 250 V AC
3A
10A 10m V DC
Single side stable (S type: 200 mW); latching (S type: 180 mW)
Min. 100M (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
1,000 Vrms for 1min.
(500 Vrms for 1min: 1 Form C high sensitivity type) (Detection current: 10mA.)
1,500 Vrms for 1min.
(1,000 Vrms for 1min: 1 Form C high sensitivity type) (Detection current: 10mA.)
Max. 65C
(By resistive method, nominal coil voltage applied to the coil, contact carrying current: 2A.)
Max. 10 ms [10 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 5 ms [10 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Min. 490 m/s2
Min. 490 m/s2
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10s.)
10 to 55 Hz at double amplitude of 5 mm
Min. 108 (107: 1 Form C latching type) (at 600 times/min.)
Min. 5105 rated load (at 60 times/min.)
Ambient temperature: –40C to +70C –40F to +158F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
60 times/min.
Approx. 3 g .11 oz
Approx. 4g .14oz
1* This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual
load. (TX/TX-S/TX-D relay AgPd contact types are available for low level load switching [10V DC, 10mA max. level])
2* Half-wave pulse of sine wave: 11ms; detection time: 10s
3* Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
REFERENCE DATA
1. Maximum switching capacity
2. Life curve (Resistive load)
3. Contact reliability for AC loads
Tested sample: DS2E-S-DC24V 10 pcs.
Operating speed: 20 times/min.. Detection level: 200 m
2.0
1.0
0.5
VA
C
125V
AC
250
Weibull
probability data
0.2
3
Operate time (mean)
2
Release time (mean)
1
80
100
120
Coil applied voltage, %
ds_61005_en_ds: 280114D
10
Pick-up voltage
(1) (2) (3)
OFF
OFF
ON
ON
0
–10
10
0
Drop-out voltage
OFF
ON
0
10
100
No. of operations, ×104
1,000
5-(2). Influence of adjacent mounting
(2 Form C)
OFF
ON
–10
5
10
.197
.394
Inter-relay distance , mm inch
Rate of change, %
Operate and release time, ms
4
Rate of change, %
Test condition: Without diode connected to coil in parallel
1
2
Switching current, A
5-(1). Influence of adjacent mounting
(1 Form C)
Rate of change, %
4. Operate and release time characteristics
(2 Form C single side stable type)
0
0
100mA
1A
Switching current
0.1
Rate of change, %
10mV
10A
0.5A
5.0
125 V AC
0.3A
10.0
10
10V
70.0
50.0
30.0
30 V DC
1
A 2 A 12
50V 5V
AC AC
100
99.9
99.0
95.0
0.5
100V
F(t), %
1,000
No. of operations, ×104
Contact voltage (DC)
1,000V
10
Pick-up voltage
(1) (2) (3)
OFF
OFF
ON
ON
OFF
OFF
ON
ON
0
–10
10
0
Drop-out voltage
–10
5
10
.197
.394
Inter-relay distance , mm inch
3