Features
Regulated
Converters
Description
●
●
●
●
●
●
●
2:1 and 3:1 Wide Input Voltage Ranges
1kVDC, 2kVDC and3kVDC Isolation
UL94V-0 Package Material
Continuous Short Circuit Protection
Low Ripple and Noise
Remote On/Off Control
Efficiency to 83 %
ECONOLINE
DC/DC-Converter
with 3 year Warranty
Very high power density, 2:1 or 3:1 input voltage range and a wide operating temperature
range -40°C to +71°C and extra features such as On/Off control are just some of the
characteristics of this converter which is ideal for highly sophisticated industrial
designs.The RS3 is available with 2kV or 3kV isolation options (1kVDC is standard)
3 Watt
SIP8 Isolated
Single & Dual
Output
Selection Guide
Part Number
www.recom-international.com
REV: 0/2014
RoHS
2011/65/EU
6/6
EN-60950-1 Certified
EN-60601-1 Certified*
(*/H suffix)
RS3
Derating-Graph
(Ambient Temperature)
RS3-(Z)S_D
100
80
Output Power (%)
Input
Rated Output Output Current Efficiency
Max
Voltage Range
Voltage
Full Load
typ.
Capacitive
SIP8
(VDC)
(VDC)
(mA)
(%)
Load(1)
RS3-xx3.3S (H2/H3) 4.5-9, 9-18
3.3
600
73-75
4700µF
18-36, 36-72
77-78
RS3-xx05S (H2/H3) 4.5-9, 9-18
5
600
76-79
4700µF
18-36, 36-72
80-81
RS3-xx09S (H2/H3) 4.5-9, 9-18
9
333
77-80
3300µF
18-36, 36-72
81-82
RS3-xx12S (H2/H3) 4.5-9, 9-18
12
250
80-81
2200µF
18-36, 36-72
83
RS3-xx15S (H2/H3) 4.5-9, 9-18
15
200
80-81
2200µF
18-36, 36-72
83
RS3-xx3.3D (H2/H3) 4.5-9, 9-18
±3.3
±300
73-75
±2200µF
18-36, 36-72
75
RS3-xx05D (H2/H3) 4.5-9, 9-18
±5
±300
76-80
±2200µF
18-36, 36-72
80-81
RS3-xx09D (H2/H3) 4.5-9, 9-18
±9
±167
77-81
±2200µF
18-36, 36-72
81
RS3-xx12D (H2/H3) 4.5-9, 9-18
±12
±125
78-83
±1000µF
18-36, 36-72
83
RS3-xx15D (H2/H3) 4.5-9, 9-18
±15
±100
79-83
±1000µF
18-36, 36-72
83
RS3-xx3.3SZ (H2/H3)
9-27
3.3
600
73
4700µF
20-60
74
RS3-xx05SZ (H2/H3)
9-27
5
600
76-79
4700µF
20-60
78
RS3-xx09SZ (H2/H3)
9-27
9
333
77
3300µF
20-60
79
RS3-xx12SZ (H2/H3)
9-27
12
250
80
2200µF
20-60
80
RS3-xx15SZ (H2/H3)
9-27
15
200
80
2200µF
20-60
80
RS3-xx3.3DZ (H2/H3)
9-27
±3.3
±300
73
±2200µF
20-60
74
RS3-xx05DZ (H2/H3)
9-27
±5
±300
77
±2200µF
20-60
78
RS3-xx09DZ (H2/H3)
9-27
±9
±167
79
±2200µF
20-60
79
RS3-xx12DZ (H2/H3)
9-27
±12
±125
80
±1000µF
20-60
80
RS3-xx15DZ (H2/H3)
9-27
±15
±100
80
±1000µF
20-60
80
No suffix is standard isolation (1kVDC) e.g, RS3-0505S
*add suffix /H2 or /H3 for 2kVDC or 3kVDC isolation, e.g, RS3-0505S/H2, R3S-0505DZ/H3
60
40
30
20
0
Safe Operating Area
-40
0
50
71
Operating Temperature °C
2:1 Input
(RS3-S/D)
xx = 4.5-9Vin = 05
xx = 9-18Vin = 12
xx = 18-36Vin = 24
xx = 36-72Vin = 48
85
150
3:1 Input
(RS3-SZ/DZ)
xx = 9-27Vin = 24
xx = 20-60Vin = 48
Refer to Application Notes
E-133