HOME在庫検索>在庫情報

部品型式

G6Y-1DC24

製品説明
仕様・特性

G6Y High-frequency Relay Switching Structure Based on the MicroStrip Line is Used to Combine High Performance and Cost-effectiveness • Isolation characteristics of 65 dB or better at 900 MHz • Effective insertion loss characteristics of 0.2 dB or better at 900 MHz (half the loss of earlier models) • Fully sealed construction provides excellent environmental resistance. • Improved shock-resistance (double the resistance of earlier models) RoHS Compliant ■Model Number Legend G6Y-@ @ V CD —— Application Examples 1. Number of contact poles 1: Single pole (SPDT contact) 1 2 ■Standard Specifications • • • • Contact Mechanism: Double-braking bifurcated contact Contact Material: Gold alloy Sealing: Fully sealed Terminal Configuration: Printed circuit board terminal configuration ■Ordering Information Classification Basic type Structure Contact form SPDT Model G6Y-1 Fully sealed Rated coil voltage 4.5 VDC 5 VDC 9 VDC 12 VDC 24 VDC Signal Switching in Various Communications Equipment • Wired Communications: Cable TV, captain systems, and video response systems (VRS) • Wireless Communications: Transceivers, ham radio, car telephones, high-level TV, fax machines, satellite broadcasting, text multiplex broadcasting, and pay TV • Public Equipment: VCRs, TVs, video disk players, and TV games • Industrial Equipment: Measuring equipment, test equipment, and multiplex transmission devices ■Characteristics Minimun packing unit 100 pcs/tray Note: Please clearly indicate the coil rated voltage (V) when ordering. Example: G6Y-1 DC4.5 In addition, the delivered product and its package will be marked with voltage specification of @@ VDC. ■Ratings Coil Item Classification Rated voltage 4.5 VDC 5 VDC 9 VDC Basic type 12 VDC 24 VDC Rated current (mA) 44.4 40.0 22.2 16.7 8.3 Coil resistance (Ω) 101 125 405 720 2,880 Operating voltage (V) Must release voltage (V) Max. voltage (V) Power consumption (mW) 75% max. 10% min. 150% at 23°C Approx. 200 Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. The Operating characteristics are measured at a coil temperature of 23°C. 3. The “Max. allowed voltage” is the maximum voltage that can be applied to the relay coil. It is not the maximum voltage that can be applied continuously. Contacts High-frequency Characteristics *1 Item Item Frequency 250 MHz 900 MHz 2.5 GHz Isolation 80 db min. 65 dB min. 30 dB min. − Insertion loss 0.5 dB max. 0.5 dB max. V.SWR 1.5 max. 1.5 max. − Max. carry power 10 W − Max. switching power 10 W *2 − Note 1. The impedance of the measuring system is 50 Ω. 2. The table above shows preliminary values. *1. Contact your Omron representative if the relay will be used in applications that require high repeatability with high-frequency characteristics in microload regions. *2. This value is for a load with V.SWR x 1.2. Load Resistive load 0.01 A at 30 VAC Rated load 0.01 A at 30 VDC 900 MHz, 1 W * Rated carry current 0.5 A 30 VAC Max. switching voltage 30 VDC Max. switching current 0.5 A Max. switching power AC10VA (reference value) DC10W * This value is for a load with V.SWR x 1.2. Contact resistance *1 Operating time Release time Insulation resistance *2 between coil and contacts between contacts of same polarity Dielectric strength between coil and ground and between contacts and ground 100 mΩ max. 10 ms max. (approx. 5 ms) 5 ms max. (approx. 1 ms) 100 MΩ min. 1,000 VAC, 50/60 Hz for 1 min 500 VAC, 50/60 Hz for 1 min 500 VAC, 50/60 Hz for 1 min 10 Hz to 55 to 10 Hz, 0.75-mm single amplitude (1.5 mm double amplitude) Vibration resistance 10 Hz to 55 to 10 Hz, 0.75-mm Malfunction single amplitude (1.5 mm double amplitude) Destruction 1,000 m/s2 Shock resistance Malfunction 500 m/s2 1,000,000 operations min. Mechanical (at 1,800 operations/hr) Durabiltiy 300,000 operations min. Electrical (under rated load at 1,800 operations/hr) Ambient operating -40°C to 70°C (with no icing) temperature Ambient operating 5 to 85% humidity Weight Approx. 5 g Destruction Note: The table above shows preliminary values. *1. Measurement Conditions: 5 VDC, 100 mA, voltage drop method *2. Measurement Conditions: Measured at the same points as the dielectric strength using a 500-VDC ohmmeter. 1 G 6 Y

ブランド

OMRON

会社名

オムロン株式会社

事業概要

センシング&コントロール技術を核とした産業向け制御機器やシステム、電子部品のほか、ヘルスケア製品等を展開する「オムロングループ」の中核企業の役割を担っている。

供給状況

 
Not pic File
お求め部品G6Y-1DC24は、クレバーテックのスタッフが市場調査を行いemailにて御回答致します。

「見積依頼」をクリックして どうぞお進み下さい。

お支払方法

宅配業者の代金引換又は商品到着後一週間以内の銀行振込となります。


お取引内容はこちら
G6Y-1DC24の取扱い販売会社 株式会社クレバーテック  会社情報(PDF)    戻る


0.1631228924