Ordering information
On-board type
SUCW3
SUC W
1
2
3
3
12 12
4
5
B
6
P
7
-O
8
1Series name
2Dual output
3Output wattage
4Input voltage
5Output voltage
6Mounting type
B :SMD
C :DIP
7Packing form
Blank:Plastic cover
P :Tray (SMD type)
8Optional
G :Capacitor between
Input and Output is
removed.
R
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
SUCW30512
3.12
VOLTAGE[V] *1 t12 or +24
CURRENT[A] 0.13
SUCW30515
3
t15 or +30
0.1
SUCW31212
3.12
t12 or +24
0.13
SUCW31215
3
t15 or +30
0.1
SUCW32412
3.12
t12 or +24
0.13
SUCW32415
3
t15 or +30
0.1
SUCW34812
3.12
t12 or +24
0.13
SUCW34815
3
t15 or +30
0.1
SUCW31215 SUCW32412
DC18 - 36
0.329typ
0.172typ
76typ
76typ
t15(+30)
t12(+24)
SUCW32415 SUCW34812
DC36 - 76
0.165typ
0.086typ
76typ
76typ
t15(+30)
t12(+24)
SUCW34815
0.1
75max
750max
120max
150max
150max
200max
180max
290max
60max
0.1
75max
750max
120max
150max
150max
200max
180max
290max
60max
SPECIFICATIONS
INPUT
SU.SUC
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY
OTHERS
*1
*2
*3
*4
*
MODEL
VOLTAGE[V]
*2
CURRENT[A]
*2
EFFICIENCY[%]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
-20 to +55C *3
RIPPLE[mVp-p]
-40 to -20C *3
-20 to +55C *3
RIPPLE NOISE[mVp-p]
-40 to -20C *3
-20 to +55C
TEMPERATURE REGULATION[mV]
-40 to +55C
*4
DRIFT[mV]
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE
OUTPUT VOLTAGE SETTING[V] (t5%)
OVERCURRENT PROTECTION
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-CASE
OUTPUT-CASE
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CASE SIZE/WEIGHT
COOLING METHOD
SUCW30512
DC4.5 - 9
0.844typ
74typ
t12(+24)
SUCW30515 SUCW31212
DC9 - 18
0.811typ
0.343typ
74typ
76typ
t15(+30)
t12(+24)
0.13
0.1
0.13
60max
75max
60max
600max
750max
600max
120max
120max
120max
150max
150max
150max
150max
150max
150max
200max
200max
200max
150max
180max
150max
240max
290max
240max
50max
60max
50max
20max (Minimum input, Io=100%)
Fixed (TRM pin open) t5% adjustable
0.13
60max
600max
120max
150max
150max
200max
150max
240max
50max
by external VR
11.40 - 12.60 14.25 - 15.75 11.40 - 12.60 14.25 - 15.75 11.40 - 12.60 14.25 - 15.75 11.40 - 12.60 14.25 - 15.75
Works over 105% of rating and recovers automatically
Provided (Negative logic L : ON, H : OFF)
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
-40 to +85C, 20 - 95%RH (Non condensing) (Required Derating), 3,000m (10,000feet) max
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 98.0m/s2 (10G), 3minutes period, 60minutes each along X, Y and Z axis
490.3m/s2 (50G), 11ms, once each along X, Y and Z axis
UL60950-1, C-UL, EN60950-1
25X7.0X16.1mm (WXHXD) / 5g max
Convection/Forced air
Output pins can be connected in series to make a 24V/30V output.
Rated input 5V, 12V, 24V or 48V DC Io=100%
Ripple and Ripple Noise is measured by using measuring board with capacitor with in 25mm from output pin terminals.
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
Parallel operation with other model is not possible.
G-30
0.13
60max
600max
120max
150max
150max
200max
150max
240max
50max
0.083typ
76typ
t15(+30)
0.1
75max
750max
120max
150max
150max
200max
180max
290max
60max