G6D
PCB Power Relay
Slim, Miniature Relay, Capable
of Relaying Programmable
Controller and Temperature
Controller Outputs
• Reduced board space, ideal for high-density mounting (45%.
(6.5 mm (W) × 17.5 mm (L) × 12.5 mm (H))
• Small, yet switches 5 A at 250 VAC/30 VDC.
• Allows 300,000 operations with a 2-A load at 250 VAC or
30 VDC.
RoHS Compliant
■Model Number Legend
■Application Examples
G6D- @ @- @- @
—— — —
• Ideal for output applications of control
equipments.
1 2 3 4
1. Number of Poles
1: 1-pole
3. Contact Material
ASI: Silver alloy
(cadmium-free)
2. Contact Form
A: SPST-NO (1a)
■Characteristics
4. Contact surface
AP: Au plated
■Ordering Information
Enclosure rating
Contact form
Terminal shape
Rated coil voltage
Model
Minimun packing
unit
5 VDC
12 VDC
24 VDC
12 VDC
24 VDC
25 pcs/tube
G6D-1A-ASI
Fully sealed
SPST-NO (1a)
PCB terminals
G6D-1A-ASI-AP
●Connecting Socket
Model
P6D-04P
Minimun packing unit
25 pcs
■Ratings
●Coil
Item
Rated voltage
5 VDC
12 VDC
24 VDC
Rated
current
(mA)
Coil
resistance
(Ω)
40
16.7
8.3
125
720
2,880
Must operate Must release
Max.
voltage
voltage
voltage
(V)
(V)
(V)
% of rated voltage
70% max.*
10% min.
160%
(at 23•C)
Power
consumption
(mW)
Approx. 200
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of
±10%.
*2.
The operating characteristics are measured at a coil temperature of 23°C.
*3.
The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
* The must operate voltage is 75% or less of the rated voltage if the relay is mounted upside down.
●Contacts
Item
Contact Type
Load
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
*
Resistive load
Single
Ag-Alloy (Cd free)
(Ag-alloy (Cd free) and Au plated)
5 A at 250 VAC
5 A at 30 VDC
5A
250 VAC, 30 VDC
5A
The content indicated in parentheses ( ) are for the G6D-1A-ASI-AP.
Contact resistance *1
Operate time
Release time
Insulation resistance *2
Between coil
and contacts
Dielectric Between
strength
contacts of
the same
polarity
Impulse withstand voltage
(between coil and contacts)
100 mΩ max.
10 ms max.
5 ms max.
1,000 MΩ min.
3,000 VAC, 50/60 Hz for
1 min
750 VAC, 50/60 Hz for
1 min
6 kV (1.2 x 50 μs)
10 to 55 to 10 Hz, 0.75 mm
single amplitude (1.5 mm
double amplitude)
Vibration
resistance
10 to 55 to 10 Hz, 0.75 mm
Malfunction
single amplitude
(1.5 mm double amplitude)
Destruction
1,000 m/s2
Shock
resistance Malfunction
100 m/s2
20,000,000 operations min.
Mechanical
(at 18,000 operations/hr)
70,000 operations min.
(5 A at 250 VAC, resistive
load)
70,000 operations min.
(5 A at 30 VDC, resistive
Durability
load)
Electrical
300,000 operations min.
(2 A at 250 VAC, resistive
load)
30,000 operations min.
(2 A at 30 VDC, resistive
load)
(at 18,000 operations/hr)
Failure rate (P level)
10 mA at 5 VDC
(reference value *3)
(1 mA at 5 VDC) *4
Ambient operating
-25•C to 70•C (with no icing
temperature
or condensation)
Ambient operating humidity 5% to 85%
Weight
Approx. 3 g
Destruction
Note. When ordering, add the rated coil voltage to the model number.
Example: G6D-1A-ASI 5 VDC
Rated coil voltage
Applicable relay
G6D-1A-ASI
G
6
D
Note. The data given above are initial values.
*1. Measurement conditions: 5 VDC, 1 A, voltage
drop method.
*2. Measurement conditions: The insulation
resistance was measured with a 500 VDC
megohmmeter at the same locations as the
dielectric strength was measured.
*3. This value was measured at a switching
frequency of 120 operations/min.
*4. The values indicated in parentheses ( ) are
for the G6D-1A-ASI-AP.
1