IC149 Series (SMT)
QFP/TQFP - 100 Pins (25x25) 0.5mm pitch
Part Number (Details)
Specifications
Insulation Resistance:
Withstanding Voltage:
Contact Resistance:
Operating Temp. Range:
Reflow-soldering Temp.:
Mating Cycles:
Solvent Durability:
Allowable Torque (max.):
500MΩ at 150V DC
100Veff to 700Veff for 1 minute
30mΩ max. at 10mA and 20mV
-25°C to +85°C
220°C for 60 seconds
20 insertions maximum
Freon
- for 1-time screw connection
= max 0.147 Nm
- for repetitive screw connection = min 0.078 Nm
max 0.098 Nm
IC149
- 100 - *54 - *5 1
Series No.
No. of Contact Pins
Positioning Pins:
0 = Without Pins
1 = With Pins
Contact Plating:
S = SnPb (for IC-socket Use)
B = Gold (for Adapter Use)
Materials and Finish
Housing: Polyphenylenesulfide (PPS) glass filled UL94V-0
Contact: Beryllium Copper (BeCu)
Plating: SnPb 2.0 ~ 4.0µm over 2.5 ~ 4.5µm Ni = S5
Au 0.3µm min. over 2.5 ~ 4.5µm Ni = B5
0 = without Screws
1 = with Screws
Compatible Emulation-Adapter
ICP-100-5
Outline Socket Dimensions (Reference Only)
27.00
Remarks
13.20
15.40
*
15.30 x 15.30
27.00
1. Ensure a clean contact area. Fluxes, dust and other impurifications
may cause corrosion and contact problems.
2. This Socket is not for automatic production. It is particulary suitable
for the development of software stored in ROM and for testing LSI-IC's.
3. Careful attention must be taken when fixing the Socket, since it is
entirely made from thermoplastic material. If the max. torque is
exceeded, the Socket will be damaged beyond repair.
4. If using the Socket with an Adapter, please use the gold-plated
Socket version.
* Notice
This socket is the same as IC149-100-*25-S5, except
it is higher to enable an easier soldering by hand
IC - Dimensions
Socket PCB-Layout
Top View from Socket
0
9
0
1
5
4
/
9
8
0
h
c
i
n
u
Detail A
M
S
C
I
N
O
R
T
C
E
L
E
I
H
C
I
A
M
A
Y
N3
N1
Detail C
Notes
N1: Metal soldering Tab Clip. Socket may be stabilized
by soldering (Reflow) in these 4 areas.
N3: These holes are only necessary for use with positioning pins.
SPECIFICATIONS ARE SUBJECT TO ALTERATION WITHOUT PRIOR NOTICE – DIMENSIONS IN MILLIMETER