General Purpose Relays
PCB Relays
SCHRACK
Power Relay RF
n 1
pole 16A, 1 form A (NO) or 1 form B (NC) contact
power 400mW
n Reinforced insulation (EN 61810, 60335, 60730)
n Ambient temperature up to 105°C
n Quick connect terminals for load side
n WG version: Materials in accordance to IEC 60335-1
n Coil
Typical applications
Oven control, electric heating, power supplies, air conditioning, microwave
ovens, hobs
VZ
Approvals
Coil Data
VDE REG.-Nr. A652, UL E214025, CQC 05001014817
Coil voltage range
Operative range, IEC 61810
Coil insulation system according UL1446
Technical data of approved types on request
Contact Data
Contact arrangement 1 form A (NO) or 1 form B (NC)
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
16A
Limiting making current, form A contact,
max. 4s, duty factor 10 %
25A
Breaking capacity max.
4000VA
Contact material
AgNi 90/10
Min. recommended contact load
12VAC at 500mA
Frequency of operation, with/without load
360/72000h-1
Operate/release time max.
11/7ms
Bounce time max., form A/form B
4/4ms
Contact ratings
Type
IEC 61810
RF334; RFH34
RF334; RFH34
RF334; RFH34
RF334; RFH34
RF354; RFH54
RF354; RFH54
RF354; RFH54
RFH34
RFH34
RFH34
RFH34
Contact Load
A (NO)
A (NO)
A (NO)
A (NO)
B (NC)
B (NC)
B (NC)
A (NO)
A (NO)
A (NO)
A (NO)
5 to 60VDC
2
class F
Coil versions, DC coil
Coil
Rated
Operate
Release
Coil
Rated coil
code voltage voltage voltage
resistance
power
VDC VDC VDC
Ω±10%
mW
005 5 3.5 0.5 62 403
006 6 4.2 0.6 90 400
009 9 6.3 0.9 203 399
012 12 8.4 1.2 360 400
024 24 16.8 2.4 1440 400
048 48 33.6 4.8 5520 417
060 60 42.0 6.0 8570 420
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Cycles
16A, 250VAC resistive, 85°C
11A, 250VAC resistive, 85°C
20A, 250VAC resistive, 85°C
25A, 250VAC resistive, 70°C
16A, 250VAC resistive, 85°C
20A, 250VAC resistive, 85°C
25A, 250VAC resistive, 70°C
16A, 250VAC resistive, 105°C
11A, 250VAC resistive, 105°C
18.5A, 250VAC resistive, 105°C
10A, 400VAC resistive, 105°C
Mechanical endurance
F0273-BI
100x103
250x103
25x103
15x103
100x103
50x103
20x103
100x103
250x103
20x103
150x103
>10x106 operations
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
Clearance/creepage
between contact and coil
Material group of insulation parts
Tracking index of relay base
11-2011, Rev. 1111
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
1000Vrms
4000Vrms
≥8/8mm
IIIa
PTI250V
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
1