Please contact us about
TÜV certified products.
Certified
AQ2A2-ZP3/28VDC, AQ2A2-J-ZP3/28VDC,
AQ5A2-ZP3/28VDC, AQ1AD2-3/28VDC
and AQ2AD1-3/28VDC
Certified
AQ2A2-ZP3/28VDC, AQ2A2-J-ZP3/28VDC,
AQ5A2-ZP3/28VDC, AQ1AD2-3/28VDC
and AQ2AD1-3/28VDC
High capacity up to 10A
PCB terminal type SSR
Certified
AQ2A2-ZP3/28VDC, AQ2A2-J-ZP3/28VDC,
AQ5A2-ZP3/28VDC, AQ1AD2-3/28VDC and
AQ2AD1-3/28VDC
VDE
Certified
AQ3A2-ZT4/32VDC,
AQ3A2-J-ZT4/32VDC and
AQ10A2-ZT4/32VDC
AQ1 RELAYS
FEATURES
Compliance with RoHS Directive
ORDERING INFORMATION
AQ
Load current
1 A, 2 A, 3 A, 5 A, 10 A
Load voltage
2: 75 to 250 V AC
D1: 3 to 60 V DC
D2: 10 to 200 V DC
Shape
Nil: Vertical type
J: Flat type
Nil: DC output
ZP: Zero-cross AC output (Photocoupler)
ZT: Zero-cross AC output (Phototriac coupler)
Input voltage
3/28 V DC: 3 to 28 V DC
4/32 V DC: 4 to 32 V DC
* Random types are available upon request.
ASCTB24E 201108-T1
1. 10A high-capacity realized for PC
board terminal (when using heat sink)
SSR for compact PC boards with 10 A
capacity that is two times greater than
our previous model. It is suitable for longlife, highly frequent control.
2. VDE (EN60950-1) reinforced
insulation compliant
Fully satisfies demand for safety by
guaranteeing compliance with
EN60950-1 safety standard and featuring
3,000 V reinforced insulation (AQ3A2ZT4/32VDC, AQ3A2-J-ZT4/32VDC and
AQ10A2-ZT4/32VDC).
3. Superior anti-vibration and antishock characteristics
The body is molded as a single unit with
flame resistant resin which makes it
highly resistant against vibration and
shock, and gives it superior protection
from environment. The body can also be
washed.
4. Vertical types with SIL terminal
arrangement and flat types are
available.
1) The vertical type is available in
thicknesses of 10 mm (2 A and 3 A types)
and 12 mm (5 A and 10 A types).
Terminal arrangement is SIL in integral
multiples of 2.54 mm (0.1 inch).
2) The height of the flat type is 12 mm.
The terminal arrangement is DIL in
integral multiples of 2.54 mm.
5. Reduced noise generation
The load will operate at close to zero
voltage even when the input signal is
applied during a cycle. Also, even if an
input signal is cancelled during a cycle,
the load is cut off at close to zero current.
For this reason, hardly any noise is
produced and radio frequency
interference (RFI) and electromagnetic
interference (EMI) are kept to a minimum.
6. Built-in snubber circuit prevents
malfunction.
TYPICAL APPLICATIONS
• Printing machines
• Packing machines
• Traffic signal control
• Automatic ticket punchers
• Terminal equipment of data processing
• Computer peripherals
• NC machines