GL560/GL561
GL560/GL561
Low Peak Forward Voltage Type
φ 5 Resin Mold Package Infrared
Emitting Diodes
s Features
s Outline Dimensions
GL561
audio equipment and air conditioners
φ 5 + 0.15
- 0.15
Colorless
transparent
resin
8.3 ± 0.2
1. Infrared remote controllers for TVs, VCRs,
7.3 ± 0.2
s Applications
Colorless
φ 5 + 0.15 transparent
- 0.15
resin
0.8 ± 0.2
2. φ 5 resin mold package
0.8 ± 0.2
Protruded resin 1.5MAX
GL560
Protruded resin 1.5MAX
1. Low peak forward voltage suitable for battery drive
( VFM : TYP.1.7V at I FM : 0.5A)
(Unit : mm)
GL561
25
± 13
*1
*2
Parameter
Forward current
Peak forward current
Reverse voltage
Power dissipation
Operating temperature
Storage temperature
Soldering temperature
Symbol
IF
I FM
VR
P
Topr
Tstg
Tsol
2
1
(2.54 )
Unit
mA
A
V
mW
˚C
˚C
˚C
2
(2.54 )
0.8
5.8 ± 0.2
(Ta=25˚C)
Rating
100
1
6
150
- 25 to + 85
- 40 to + 85
260
1
0.5 ± 0.1
s Absolute Maximum Ratings
2
5.8 ± 0.2
GL560
14
± 21
0.5 ± 0.1
Model
Radiant intensity TYP. (mW/sr)
Half intensity angle TYP. ( ˚ )
0.5 ± 0.1
0.3MIN
s Model Lineup
23.5 ± 1
0.5 ± 0.1
0.3MIN
23.5 ± 1
Notch
1
1 Anode
2 Cathode
*1 Pulse width <=100µ s, Duty ratio=0.01
*2 For 10 seconds at the position of 2.6 mm from the resin edge
s Electro-optical Characteristics
Parameter
Forward voltage
Peak forward voltage
Reverse current
*3
Radiant intensity
Symbol
VF
V FM
IR
GL560
GL561
IE
Conditions
I F = 50mA
I FM = 0.5A
V R = 3V
I F = 50mA
λp
∆λ
Ct
fc
Peak emission wavelength
Half intensity wavelength
Terminal capacitance
Response frequency
Half intensity angle
(Ta=25 ˚C)
GL560
GL561
I F = 5mA
I F = 5mA
V R = 0, f = 1MHz
∆θ
IF = 20mA
-
MIN.
5
12
-
TYP.
1.25
1.7
14
25
940
45
50
300
± 21
± 13
MAX.
1.37
2.5
10
-
*3 I E : Value obtained by converting the value in power of radiant fluxes emitted at the solid angle of 0.01 sr (steradian) in the direction of mechanical axis of
the lens portion into 1 sr or all those emitted from the light emitting diode.
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.”
Unit
V
V
µA
mW/sr
nm
nm
pF
kHz
˚
˚