Specifications
Model
Max Output Power
Efficiency (Typ)
Input Voltage range
Input Current Typ
Inrush Current
Power Factor
Output Voltage Accuracy
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Hold Up Time (Typ)
Leakage Current
Operating Temperature
Storage Temperature
Humidity
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated EMI
Recommended EMI Filter
Weight (Typ)
Size (WxHxD)
Warranty
JWT75
W
%
A
A
V
ms
g
mm
-
JWT100
75
100
72
85 - 265VAC (47 - 63Hz) or 120 - 330VDC
1.2 / 0.6
1.4 / 0.7
14A at 100VAC, 28A at 200VAC input
Meets EN61000-3-2
V1 variable, V2 & V3 +/-5%
V1 & V2 <0.02%/ºC, V3 <0.03%/ºC
>105%
Main output only: 5.7 - 7V
20
0.75mA Max, 0.44mA typical at 230VAC
-10ºC to +65ºC, derate linearly to 50% load from 50ºC to 65ºC
-10ºC to +50ºC, derate linearly to 60% load from 40ºC to 50ºC with cover
-30 to +85ºC
30 - 90% RH (operating), 10 - 95% RH (non operating)
Convection
Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA),
Output to Ground 500VAC (100mA) for 1 min.
>100M at 25ºC & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 2G constant X, Y, Z 1 hour
<20G
UL60950-1, CSA60950-1, EN60950-1, VDE0160, CE Mark, Built to meet DENTORI
EN55011 / EN55022-B, FCC Class B, VCCI-B
RSEL-2002W
600
720
42 x 92 x 188
48 x 92 x 203
Five Years
1-800-526-2324 • www.us.tdk-lambda.com/lp/
11
Disclaimer: us.tdk-lambda.com/lp/legal.htm