G5V-1
Low Signal Relay
Ultra-miniature, Highly Sensitive
SPDT Relay for Signal Circuits
• Ultra-miniature at 12.5 × 7.5 × 10 mm (L × W × H).
• Wide switching power of 1 mA to 1 A.
• High sensitivity: 150 mW nominal coil power consumption.
• Fully-sealed construction offering environment resistance.
• Conforms to FCC Part 68 requirements for coil to contacts.
(1,500 V, 10 × 160 μs)
RoHS Compliant
■Model Number Legend
G 5 V-@
—
■Application Examples
1. Number of Poles/Contact Form
1: 1-pole/SPDT (1c)
1
• Telecommunication equipment
• Audio-visual products
■Ordering Information
Classification
-
Standard
G
5
V
1
Enclosure
Contact form Terminal Shape Model Rated coil voltage Minimum packing unit
rating
3 VDC
5 VDC
Fully
SPDT
PCB
6 VDC
G5V-1
25 pcs/tube
sealed
(1c)
terminals
9 VDC
12 VDC
24 VDC
Note: When ordering, add the rated coil voltage to the model number.
Example: G5V-1 3 VDC
Rated coil voltage
■Ratings
●Coil
●Contacts
Rated voltage
Rated
current
(mA)
3 VDC
5 VDC
6 VDC
9 VDC
12 VDC
24 VDC
50
30
25
16.7
12.5
6.25
Must operate Must release
Max. voltage
Coil
Power
voltage
voltage
(V)
resistance
consumption
(V)
(V)
(Ω)
(mW)
% of rated voltage
60
167
240
200% at
80% max.
10% min.
Approx. 150
540
23°C
960
3,840
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance
of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
4. G5V-1-2 types with a must operate voltage of 70% max. are available as special series products.
Load
Resistive load
Item
Contact type
Single crossbar
Contact
Au-alloy + Ag
material
0.5 A at 125 VAC;
Rated load
1 A at 24 VDC
Rated carry
2A
current
Max. switching
125 VAC, 60 VDC
voltage
Max. switching
1A
current
■Characteristics
Contact resistance *1
Operate time
Release time
Insulation resistance *2
Dielectric
strength
Vibration
resistance
Shock
resistance
Durability
Between coil and contacts
Between contacts of the same polarity
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
Failure rate (P level) (reference value) *3
Ambient operating temperature
Ambient operating humidity
Weight
100 mΩ max.
5 ms max.
5 ms max.
1,000 MΩ min. (at 500 VDC between coil and contacts,
at 250 VDC between contacts of same polarity.)
1,000 VAC, 50/60 Hz for 1 min
400 VAC, 50/60 Hz for 1 min
10 to 55 to 10 Hz, 1.65 mm single amplitude
(3.3 mm double amplitude)
10 to 55 to 10 Hz, 1.65 mm single amplitude
(3.3 mm double amplitude)
1,000 m/s2
100 m/s2
5,000,000 operations min. (at 36,000 operations/hr)
100,000 operations min.
(under rated load, at 1,800 operations/hr)
1 mA at 5 VDC
-40°C to 70°C (with no icing or condensation)
5% to 85%
Approx. 2 g
Note: The values here are initial values.
*1. Measured with 10 mA at 1 VDC with a voltage drop
method.
*2. Measured with a 500 VDC megohmmeter between
coil and contacts and a 250 VDC megohmmeter
between contacts with the same polarity applied to
the same parts as those used for checking the
dielectric strength.
*3. This value was measured at a switching frequency
of 120 operations/min and the criterion of contact
resistance is 100 Ω.
This value may vary depending on the switching
frequency and operating environment. Always
double-check relay suitability under actual operating
conditions.
1