AJ8 (J8)
AJ8 (J8)
SWITCHES
POWER ROCKER SWITCH
FEATURES
AJ8 switch standard actuator
1. Power rocker switches for safety
requirements.
• All versions comply with ClassII
EN61058-1 insulation grade.
Insulation distance: 8mm Min.
Contact gap: 3mm Min.
• International Standard-approved
status
AJ8 switch Wide actuator
AJ8
switch
Already approved
UL, CSA, VDE, TÜV,
ÖVE, KEMA, SEMKO,
NEMKO, DEMKO,
FIMKO, SEV
UL, CSA, VDE, TÜV,
SEMKO, NEMKO,
DEMKO, FIMKO, SEV,
KEMA, ÖVE
Standard
actuator
type
Wide
actuator
type
2. High inrush current resistance is
ideal for office automation equipment.
RoHS Directive compatibility information
http://www.nais-e.com/
Type
Inrush
AJ8
160A
Contact
rating
16A 250V AC
Expected
life
Min.104
PRECAUTIONS WHEN
USING CADMIUM-FREE
CONTACT TYPE
Models with cadmium-free contacts have
been introduced in order to reduce
environmentally harmful substances. (“F”
is affixed to the end of the part number.)
We ask customers who are currently
using products with cadmium-containing
contacts (no “F” at the end of the part
number) to please make the switch to
models with cadmium-free contacts.
When switching, operating life may differ
depending on the load. Please be sure to
verify this by conducting an evaluation
using actual equipment.
Force
3. Operation that only requires a light
touch
The best operation characteristics were
sought by analyzing touch data gathered
by monitoring 1,500 people.
• Power Rocker Switch touch curve
4. A broad product line
The AJ8 switches are available with five
different types of terminals:quick-connect
terminals, soldering terminals, PC board
terminals, right angle terminals and left
angle terminals.
5. Eight standard actuator colors
White, black, red, dark gray, light gray,
blue, green, yellow
6. Cadmium-free contact compatibility.
Stroke
CONSTRUCTION
Case
Snap-in Clip
;; ;; ;
;;;;;;;;
;;;;;
;;;;;
;;;;
;
;;;;;;;
;;; ;
;; ;
;;;
Actuator
Contact gap (more than 3mm)
The EN60950 (intended for office automation equipment)
conforms with a 3mm gap.
When directly opening or closing the primary power supply
side, a contact gap of at least 3mm is required in order to
ensure safety.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.