DATASHEET
Common-mode Chokes RN series
Current-compensated Chokes
Rated currents from 0.3 to 10 A
Approvals
DC to 1kHz frequency
100kHz to 3MHz common-mode resonance
frequency
Dual-choke configurations
Multiple PCB-mounting options
RN chokes are attenuating common-mode or
asymmetric (P/N –> E) interference signals, by being
connected in series with the phase and neutral lines
of an AC powerline input. Symmetrical components
of the noise are also attenuated by the leakage
inductance of the windings. These chokes are
typically used in conjunction with suppression
capacitors.
Features and benefits
High saturation resistance and excellent thermal
behavior
Through hole pin connections
Dual-choke configuration
Small compact design
Multiple housing options
Custom-specific versions are available on request
Technical specifications
Flammability corresponding to
High potential test voltage
winding-to-housing @ 25°C
winding-to-winding @ 25°C
Typical applications
UL 94 V-0
Maximum continuous operating voltage
4000 VAC, 60 sec, guaranteed
1500 VAC, 60 sec, guaranteed
1500 V, 50 Hz, 2 sec, factory test
250 VAC
MTBF @ 40°C/230V (Mil-HB-217F)
Operating frequency
Rated currents
Surge current @ 10msec
Temperature range (operation and storage)
> 5,000,000 hours
50/60 Hz
0.3 to 10 A @ 40 °C max.
20 x Inominal @ 25°C
-40 °C to +125 °C (40/125/56)
Phase-angle control circuits in combination with
saturating chokes
EMI input filters
For suppressing equipment with no earth
connection
Suppressing high interference levels
Typical electrical schematic