PF Series
500 to 1500W Power Factor Correction Modules
Features
Suitable for use in Custom Power Supplies
Parallel operation
0.5” profile
Power Factor Corrected
Operation up to 85°C
Key Market Segments & Applications
Specifications
Model
AC Input Voltage range & Frequency
Input Frequency
Output Voltage
Output Power at 100/200VAC
Load Regulation
Line Regulation
Inrush Current
Efficiency (typ) at full load
Power Factor
Overcurrent Protection
Overvoltage Protection
Thermal Shutdown
AC Fail Signal
Inverter Good Signal
Enable Signal
Parallel Connection
Auxiliary Output Voltage
Operating Baseplate Temperature
Storage Temperature
Cooling
Withstand Voltage
Safety Agency Approvals
Weight
Size (WxHxD)
Warranty
PF500A-360
VAC
VDC
W
%
V
°C
°C
g
mm
yrs
PF1000A-360
85-265 wide range
47 - 63Hz
360
504/756W
1008/1512W
10V
5V typical
External pins provided connection for in rush resistor
90% (100VAC), 95% (200VAC)
Meets EN61000-3-2 (0.95 typical)
Converter shutdown
390 - 400VDC, manual reset
Shuts down Inverter, manual reset
Yes, when inverter is operating correctly
Signal provided to enable “PH” DC-DC converters
Single wire current share
Yes - see installation manual
-20 to +85°C (no derating)
-40 to +85
Conduction (see installation manuals for heatsinks)
Input - Ground 3kVAC for 1 min
UL60950-1, CSA22.2 No.60950-1, EN60950-1, & CE Mark
130
200
See output line drawings
Two Years
Notes: Consult Installation Manual for detailed specifications, test methods and application notes
1-800-526-2324 • www.us.tdk-lambda.com/lp/
120
Disclaimer: us.tdk-lambda.com/lp/legal.htm