G6Y
High-frequency Relay
Switching Structure Based on the
MicroStrip Line is Used to Combine High
Performance and Cost-effectiveness
• Isolation characteristics of 65 dB or better at 900 MHz
• Effective insertion loss characteristics of 0.2 dB or better at 900 MHz
(half the loss of earlier models)
• Fully sealed construction provides excellent environmental resistance.
• Improved shock-resistance (double the resistance of earlier models)
RoHS Compliant
■Model Number Legend
G6Y-@ @ V CD
——
Application Examples
1. Number of contact poles
1: Single pole (SPDT contact)
1 2
■Standard Specifications
•
•
•
•
Contact Mechanism: Double-braking bifurcated contact
Contact Material: Gold alloy
Sealing: Fully sealed
Terminal Configuration: Printed circuit board terminal
configuration
■Ordering Information
Classification
Basic type
Structure
Contact form
SPDT
Model
G6Y-1
Fully sealed
Rated coil voltage
4.5 VDC
5 VDC
9 VDC
12 VDC
24 VDC
Signal Switching in Various Communications Equipment
• Wired Communications: Cable TV, captain systems, and video
response systems (VRS)
• Wireless Communications: Transceivers, ham radio, car
telephones, high-level TV, fax machines, satellite broadcasting,
text multiplex broadcasting, and pay TV
• Public Equipment: VCRs, TVs, video disk players, and TV games
• Industrial Equipment: Measuring equipment, test equipment, and
multiplex transmission devices
■Characteristics
Minimun packing unit
100 pcs/tray
Note: Please clearly indicate the coil rated voltage (V) when ordering.
Example: G6Y-1 DC4.5
In addition, the delivered product and its package will be marked with voltage specification of @@ VDC.
■Ratings
Coil
Item
Classification Rated voltage
4.5 VDC
5 VDC
9 VDC
Basic type
12 VDC
24 VDC
Rated
current
(mA)
44.4
40.0
22.2
16.7
8.3
Coil
resistance
(Ω)
101
125
405
720
2,880
Operating
voltage
(V)
Must release
voltage
(V)
Max.
voltage
(V)
Power
consumption
(mW)
75% max.
10% min.
150% at
23°C
Approx. 200
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of
±10%.
2. The Operating characteristics are measured at a coil temperature of 23°C.
3. The “Max. allowed voltage” is the maximum voltage that can be applied to the relay coil. It is not the
maximum voltage that can be applied continuously.
Contacts
High-frequency Characteristics *1
Item
Item Frequency
250 MHz
900 MHz
2.5 GHz
Isolation
80 db min. 65 dB min. 30 dB min.
−
Insertion loss
0.5 dB max. 0.5 dB max.
V.SWR
1.5 max.
1.5 max.
−
Max. carry power
10 W
−
Max. switching power
10 W *2
−
Note 1. The impedance of the measuring system is
50 Ω.
2. The table above shows preliminary values.
*1. Contact your Omron representative if the relay
will be used in applications that require high
repeatability with high-frequency
characteristics in microload regions.
*2. This value is for a load with V.SWR x 1.2.
Load Resistive load
0.01 A at 30 VAC
Rated load
0.01 A at 30 VDC
900 MHz, 1 W *
Rated carry current
0.5 A
30 VAC
Max. switching voltage
30 VDC
Max. switching current
0.5 A
Max. switching power
AC10VA
(reference value)
DC10W
*
This value is for a load with V.SWR x 1.2.
Contact resistance *1
Operating time
Release time
Insulation resistance *2
between coil
and contacts
between
contacts of
same polarity
Dielectric
strength
between coil
and ground
and between
contacts and
ground
100 mΩ max.
10 ms max. (approx. 5 ms)
5 ms max. (approx. 1 ms)
100 MΩ min.
1,000 VAC, 50/60 Hz for 1 min
500 VAC, 50/60 Hz for 1 min
500 VAC, 50/60 Hz for 1 min
10 Hz to 55 to 10 Hz, 0.75-mm
single amplitude (1.5 mm double
amplitude)
Vibration
resistance
10 Hz to 55 to 10 Hz, 0.75-mm
Malfunction single amplitude (1.5 mm double
amplitude)
Destruction 1,000 m/s2
Shock
resistance Malfunction 500 m/s2
1,000,000 operations min.
Mechanical
(at 1,800 operations/hr)
Durabiltiy
300,000 operations min.
Electrical
(under rated load at 1,800
operations/hr)
Ambient operating
-40°C to 70°C (with no icing)
temperature
Ambient operating
5 to 85%
humidity
Weight
Approx. 5 g
Destruction
Note: The table above shows preliminary values.
*1. Measurement Conditions: 5 VDC, 100 mA,
voltage drop method
*2. Measurement Conditions: Measured at the
same points as the dielectric strength using a
500-VDC ohmmeter.
1
G
6
Y