PV Series
Single Inline Package DC-DC Converters (1-3 Watts)
Features
u SIP style footprint
u 5V, 12V, 24V, & 48V Inputs
u Single and Dual Outputs
u Adjustable Output Voltages
u Input-Output Isolation
u Overcurrent Protection
Key Market Segments & Applications
Specifications
Model
DC Input ranges
Efficiency (typical)
Output Voltage Accuracy
Output Voltage Adjustment
Preload
Ripple & Noise
Max Line Regulation
Max Load Regulation
Overcurrent Protection
Overvoltage Protection
Temperature Coefficient
Cooling
Isolation Voltage
Isolation Resistance
Shock
Vibration
Humidity (non condensing)
Storage Humidity
Operating Temp. Range
Storage Temperature
Weight (Typ)
Size (LxWxH)
Warranty
3.3V
VDC
VDC
A
mV
mV
mV
A
%
VAC
Ohm
°C
g
in
yrs
5V
12V
5V: 4.5V-9V; 12V: 9V-18V, 24V: 18V-36V, 48V: 36V-72
77%
±5%
3.3V-3.67V
5V-6V
12V-15V
0
100mV
120mV
20mV
40mV
Auto recovery (1)
None
0.02%/°C
Convection cooled
Input-Output: 500VAC 1 min. (5mA)
Greater than 100M
20G
10-55Hz (sweep for 1 min.) 1.5mm constant amplitude max 9G X,Y,Z 2 hours each
30%-90% RH (non condensing)
10%-95% RH (non condensing)
-20 to 70°C, derate linearly to 50% load from 50 to 70°C
-30°C to +85°C
5g
1.12x0.33x0.91(PV1R5); 1.29x0.33x1.29(PV3)
Two Years
Note: See Installation Manual for full details, test methods of parameters and application notes
1) Avoid operation in short circuit or overload for more than 30 seconds
1-800-526-2324 • www.us.tdk-lambda.com/lp/
240
Disclaimer: us.tdk-lambda.com/lp/legal.htm