Surface Mounting Relay
G6K
Surface Mounting Relay with the World’s
Smallest Mounting Area and a Height of
Only 5.2 mm
■
■
■
■
■
■
■
■
Subminiature model as small as 5.2 (H) x 6.5 (W)
x 10 (L) mm is ideal for high-density mounting.
Low profile of 5.2 mm and weight of only 0.7 g
combine to improve mounting efficiency.
Models with inside-L surface mounting terminals
are available.
Consumes approximately 70% the power of a
conventional OMRON model and operates at a
current that is as low as 100 mW.
Surface mounting terminal models incorporate a
unique terminal structure with high infrared irradiation efficiency which allows the terminal temperature to rise easily when mounting the IRS, thus
ensuring excellent soldering.
Ensures a dielectric strength of 1,500 VAC and
conforms to FCC Part 68 (i.e., withstanding an
impulse withstand voltage of 1,500 V for 10 x
160 µs).
New-Y models offer an impulse withstand voltage
of 2,500 V for 2 x 10 µs (conforms to Telcordia
specifications) by optimizing the distance between
coil and contacts.
Conforms to UL1950 (File No. E41515)/CSA
C22.2 No. 950 (File No. LR24825)
RC
The above specifications are ensured as of August 1999.
RoHS Compliant
Ordering Information
Classification
DPDT
Fully sealed
Single-side
stable
PCB terminal
Surface mounting
terminal
Single-winding
latching
Single-side stable Bellcore:
2, 500 V for 2x10 µs
G6K-2P
G6KU-2P-Y
Inside-L
G6K-2G
G6KU-2G-Y
G6K-2P-Y
G6K-2G-Y
Outside-L
G6K-2F
G6KU-2F-Y
G6K-2F-Y
Note: 1. When ordering, add the rated coil voltage to the model number.
Example: G6K-2F 12 VDC
Rated coil voltage
2. When ordering tape packing, add -TR" to the model number.
Example: G6K-2F-TR 12 VDC
Tape packing
Be sure since -TR" is not part of the relay model number, it is not marked on the relay case.
3. Terminal shape
Model Number Legend
F:
Outside-L surface mounting terminal
G:
Inside-L surface mounting terminal
G6K@-@@-@ @ VDC
P:
PCB terminal
1
2 3
4 5
4. Approved standards
1. Relay function
None: UL, CSA
None: Single-side stable model
Does not conform to Telcordia specifications
U:
Single-winding latching model
Y:
UL, CSA
2. Contact form
Conforms to Telcordia specifications: 2,500 V for 2 x
10 µs
2:
DPDT
5. Rated Coil Voltage
3, 4.5, 5, 12, 24 VDC
1
G6K
■
G6K
Contact Ratings
Load
Resistive load
Rated load
0.3 A at 125 VAC; 1 A at 30 VDC
Rated carry current
1A
Max. switching voltage
125 VAC, 60 VDC
Max. switching current
1A
■
Characteristics
Item
Single-side stable models (double-pole)
G6K-2F, G6K-2G, G6K-2P
G6K-2F-Y, G6K-2G-Y,
G6K-2P-Y
Single-winding latching
model
G6KU-2F-Y, G6KU-2G-Y,
G6KU-2P-Y
Contact resistance (See note 1.)
100 mΩ max.
Operating (set) time (See note 2.)
3 ms max. (approx. 1.4 ms)
3 ms max. (approx. 1.2 ms)
Release (reset) time (See note 2.)
3 ms max. (approx. 1.3 ms)
3 ms max. (approx. 1.2 ms)
Insulation resistance (See note 3.) 1,000 MΩ min. (at 500 VDC)
Dielectric
strength
Coil and contacts
1,500 VAC, 50/60 Hz for 1 min
Contacts of different
polarity
1,000 VAC, 50/60 Hz for 1 min
Contacts of same po- 750 VAC, 50/60 Hz for 1 min
larity
Impulse
withstand
voltage
Coil and contacts
1,500 V (10 x 160 µs)
Contacts of different
polarity
1,500 V (10 x 160 µs)
2,500 V (2 x 10 µs), 1,500 V (10 x 160 µs)
Contacts of same polarity
Vibration resistance
Destruction: 10 to 55 Hz, 2.5-mm single amplitude (5-mm double amplitude) and 55 to 500 Hz,
300 m/s2 (approx. 30G)
Malfunction: 10 to 55 Hz, 1.65-mm single amplitude (3.3-mm double amplitude) and 55 to 500 Hz,
200 m/s2 (approx. 20G)
Shock resistance
Destruction: 1,000 ms2 (approx. 100G)
Malfunction: 750 ms2 (approx. 75G)
Endurance
Mechanical: 50,000,000 operations min. (at 36,000 operations/hour)
Electrical: 100,000 operations min. (with a rated load at 1,800 operations/hour)
Failure rate (P level) (See note 4.)
10 µA at 10 mVDC
Ambient temperature
Operating: −40°C to 70°C (with no icing or condensation)
Ambient humidity
Operating: 5% to 85%
Weight
Approx. 0.7 g
Note:
Note:
The above values are initial values.
1. The contact resistance was measured with 10 mA at 1 VDC with a voltage-drop method.
2. Values in parentheses are actual values.
3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking
the dielectric strength.
4. This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This
value may vary depending on the switching frequency and operating environment. Always double-check relay suitability under
actual operating conditions.
3