GU 2 Form B (AQW414)
Normally closed
DIP8-pin type
of 400V load voltage
GU 2 Form B
(AQW414)
FEATURES
9.78
.385
3.9
.154
TYPICAL APPLICATIONS
1. Approx. 1/2 the space compared
with the mounting of Two 1 Form B
PhotoMOS units
6.4
.252
• High-speed inspection machines
• Telephone equipment
• Computers
6.4
.252
9.78
.385
3.6
.142
Two 1 Form B units
2 Form B type
mm inch
1
8
2
7
3
6
4
5
2. Applicable for 2 Form B use as well
as two independent 1 Form B use
3. Controls load currents up to 0.13 A
with an input current of 5 mA
4. High speed switching: operate time
typ. 0.46 ms
5. Extremely low closed-circuit offset
voltages to enable control of small
analog signals without distortion
RoHS compliant
TYPES
Output rating*
Part No.
Load
voltage
AC/DC
dual use
Load
current
Package
400 V
100 mA
Through hole
terminal
DIP8-pin
Tape and reel packing style
Picked from the
Picked from the
1/2/3-pin side
4/5/6-pin side
Tube packing style
AQW414
Packing quantity
Surface-mount terminal
AQW414A
AQW414AX
Tape and reel
1 tube contains:
50 pcs.
1 batch contains:
500 pcs.
AQW414AZ
Tube
1,000 pcs
*Indicate the peak AC and DC values.
Note: The surface mount terminal shape indicator “A” and the packing style indicator “X” or “Z” are not marked on the device.
RATING
1. Absolute maximum ratings (Ambient temperature: 25°C 77°F)
Item
LED forward current
LED reverse voltage
Peak forward current
Power dissipation
Load voltage (peak AC)
Output
AQW414(A)
50 mA
5V
1A
75 mW
400 V
Continuous load current
Input
Symbol
IF
VR
IFP
Pin
VL
IL
0.1 A (0.13 A)
0.3 A
800 mW
850 mW
1,500 V AC
Operating
Ipeak
Pout
PT
Viso
Topr
Storage
Tstag
Peak load current
Power dissipation
Total power dissipation
I/O isolation voltage
Temperature limits
Panasonic Corporation
–40°C to +85°C –40°F to +185°F
–40°C to +100°C –40°F to +212°F
Automation Controls Business Unit
Remarks
f = 100 Hz, Duty factor = 0.1%
Peak AC, DC
( ): in case of using only 1 channel
100 ms (1 shot), VL = DC
Non-condensing at low temperatures
industrial.panasonic.com/ac/e
ASCTB51E 201201-T