G5V-2
Low Signal Relay
General-purpose, Low-cost,
Two-pole Relays for Signal Circults
• General-purpose DIL terminal layout.
• Wide switching power of 10 μA to 2 A.
• Fully-sealed type Relays standardized with bifurcated crossbar contacts. Highly
reliable in addition to its high environment resistance.
• Conforms to FCC Part 68 (impulse withstand voltage of 1,500 V for 10 x 160 µs
between coil and contacts and between contacts of the same polarity).
• High dielectric strength at 1,000 VAC between coil and contacts, and 750 VAC
between contacts of the same polarity.
• UL and CSA standard approved.
RoHS Compliant
■Model Number Legend
G 5 V-@- @
— —
1
2
■Application Examples
1. Number of Poles/ Contact form
2: 2-pole/DPDT (2c)
■Ordering Information
■Characteristics
Enclosure Contact Terminal
rating
form
shape
Model
Item
Classification
Contact resistance *1
Operate time
Release time
Insulation resistance *2
Between coil and
contacts
Dielectric
Between contacts
strength
of the same polarity
Between contacts
of different polarity
Between coil and
contacts
Impulse
Between contacts
withstand
of the same polarity
voltage
Between contacts
of different polarity
Vibration
resistance
Shock
resistance
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Durability
Electrical
Failure rate (P level) (reference
value) *3
G
5
V
2
Standard
50 mΩ max.
High-sensitivity
100 mΩ max.
7 ms max.
3 ms max.
1,000 MΩ min. (at 500 VDC)
-
Minimum
Rated coil
packing
voltage
unit
3 VDC
5 VDC
6 VDC
Standard
G5V-2
9 VDC
12 VDC
PCB
Fully
DPDT
25
24 VDC
sealed
(2c) terminals
pcs/tube
48 VDC
5 VDC
12 VDC
HighG5V-2-H1
sensitivity
24 VDC
48 VDC
Note: When ordering, add the rated coil voltage to the model number.
Example: G5V-2 3 VDC
Rated coil voltage
Classification
• Telecommunication equipment
• Security equipment
2. Classification
None: Standard
H1: High-sensitivity
1,000 VAC, 50/60 Hz for 1 min
750 VAC, 50/60 Hz
for 1 min
500 VAC, 50/60 Hz for
1 min
1,000 VAC, 50/60 Hz for 1 min
1,500 V (10 x 160 μs)
1,500 V (10 x 160 μs)
1,500 V (10 x 160 μs)
10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
1,000 m/s2
200 m/s2
100 m/s2
15,000,000 operations min.
(at 36,000 operations/hr)
AC: 100,000 operations
100,000 operations
min., DC: 300,000
min. (at 1,800
operations min.
operations/hr)
(at 1,800 operations/hr)
10 μA at 10 m VDC
-25°C to 65°C
-25°C to 70°C
Ambient operating temperature
(with no icing or
(with no icing or
condensation)
condensation)
Ambient operating humidity
5% to 85%
Weight
Approx. 5 g
Note: The above values are initial values.
*1. The contact resistance was measured with 10 mA at 1 VDC with a voltage
drop method.
*2. The insulation resistance was measured with a 500 VDC megohmmeter
applied to the same parts as those used for checking the dielectric strength.
*3. This value was measured at a switching frequency of 120 operations/min
and the criterion of contact resistance is 50 Ω. This value may vary
depending on the switching frequency and operating environment.
Always double-check relay suitability under actual operating conditions.