Aluminum Electrolytic Capacitors
LM series
1 High ripple current resistance.
1 Suited for use in power supplies and industrial controls.
1
LM
1
SPECIFICATIONS
Items
Characteristics
Capacitance Tolerance
20% (120Hz, 20BC)
Operating Temperature Range
-40 ~ +85BC
-25 ~ +85BC
16 ~ 250V
315 ~ 450V
Rated Voltage Range
Leakage Current
Dissipation Factor
(tan d)
I
3 CV or 5mA, which is greater. (After 5 minutes application of working voltage).
Measurement Frequency: 120Hz, Temperature: 20BC
Rated Voltage (V)
Low Temperature Stability
35~50
63~315
350~450
0.30
0.25
0.20
0.25
Measurement Frequency: 120Hz.
16~100
160~250
315~450
Z (-25BC) / Z (20BC)
6
4
8
Z (-40BC) / Z (20BC)
12
-
-
Rated Voltage (V)
Impedance Ratio (Max)
(
)
25
0.35
tan d (Max)
16
2,000hours, with application of working voltage at 85BC
Capacitance Change
Within
tan d
200% or less of Initial Specified Value
Leakage Current
Load Life
Initial Specified Value or less
20% of Initial Value
1,000hours, no voltage applied, at 85BC
After Test: UR to be applied for 30 minutes, 24 to 48hours before measurement.
Capacitance Change
Within
tan d
200% or less of Initial Specified Value
Leakage Current
Shelf Life
Initial Specified Value or less
20% of Initial Value
JIS C 5141 and JIS C 5102
Standards
PERMISSIBLE RIPPLE CURRENT
Temperature Coefficient
TEMP (BC)
45
60
85
Coefficient
1.60
1.30
1.00
Frequency Coefficient
Frequency (Hz)
Working Voltage (V)
120
1K
10~100
1.00
1.20
1.25
160~315
0.95
1.00
1.20
1.25
350~450
116
50
0.90
10K
0.98
1.00
1.15
1.20