2 to 40 Amp Precision Thermal Circuit Breaker
FEATURES
• 30VDC or 120VAC, 2 to 40 Amps
• Sealed assemblies, available in manual and automatic reset options
• Ignition protected
• UL Recognized E36869
DESCRIPTION
The KLIXON® PD series thermal breakers are designed to protect wiring
and meet the harshest environmental requirements. The PD series are
weatherproof sealed for protection against moisture, dust, grease,
fuel vapors and other harsh environments. The PD series breakers
are compact, lightweight and designed to interrupt short circuits or
overloads, and combine trip-free protection with fast response time.
Typical applications are protection of wire and cable of accessory circuits,
equipment and battery protection in construction and off-road equipment,
marine, recreational vehicles (RV’s), mining, agricultural equipment and
electric (hybrid) vehicles.
The PD series is used in commercial and military applications.
PERFORMANCE CHARACTERISTICS
Calibration :
200% rated current, 77°F (25°C)
2 to 10 amps : 20 to 150 seconds
12.5 to 40 amps : 8 to 50 seconds
Ultimate Trip at 77°F (25°C)
Must hold 110%, must trip 138%
Endurance
Interrupt Current Capacity
Vibration
Mechanical Shock
Salt Spray
Per SAE J553
Per SAE J553 and ABYC E-11
10G MIL-STD-202 Method 204, Condition A
MIL-STD-202 Method 213, Condition C, 100G
MIL-STD-202 Method 101D
Dielectric Strength
MIL-STD-202 Method 301, 1500VAC min
Insulation Resistance
MIL-STD-202 Method 302, Condition B,
100 MΩ min
Weight (with mounting nuts)
19
PD Series (PDA/PDM)
PDM : 48 grams max
PDA : 41 grams max
ORDERING INFORMATION
X−X−X
Configuration
PDM = Manual, sealed
PDA = Auto, sealed
Amp Rating
(2, 3, 4, 5, 6, 8, 10, 12.5, 15
17.5, 20, 25, 30, 35, 40)
Mounting Nuts
= leave blank for none
I = include optional mounting nuts