EXQ60D Series
Dual positive output
DC/DC CONVERTERS
•
•
•
•
•
•
•
•
•
•
60W High Efficiency DC/DC Converters
1
Two positive outputs
Output voltage tracking
High efficiency
Approved to EN60950 (TÜV Rheinland), UL/cUL1950
Operating baseplate temperature of -40°C to +100°C
Up to 100% load imbalance
Trim function
No minimum load
Complies with ETS 300 019-1-3/2-3
Fully compliant with ETS 300 386-1
The EXQ60 is a new high efficiency, open frame, isolated 60 Watt converter series in an
industry standard quarter-brick footprint. The EXQ60 delivers very high output current at
low voltages, and excellent useable power density for today's high end applications.
The first two models in the series feature an input voltage range of 33 to 75VDC and are
available in output voltages of 5V/3.3V and 3.3V/2.5V. The output voltage on each
model is adjustable from 90% to 110% of the nominal value. Typical efficiencies for the
models are 91% for the 5V/3.3V and 90% for the 3.3V/2.5V version. The EXQ60 series
also has a remote on/off capability. Overcurrent and overvoltage protection features are
included as standard. With full international safety approval including EN60950, (TÜV
Rheinland) and UL/cUL1950, the EXQ60 reduces compliance costs and time to market.
TÜV
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Voltage adjustability
Both outputs
±10%
Setpoint accuracy
Both outputs (See Note 1)
Output voltage
5V/3.3V
(over all line and
load conditions)
3.3V/2.5V
Minimum load
Both outputs
Ripple and noise
20MHz bandwidth
Transient response
peak dev. settling time
50% to 75% and back
120mV/80mV
to 1.0%, no external cap.
100µs
Short circuit protection
Both outputs
4.75V
3.20V
3.18V
2.39V
Tracking
±1% max.
<
<
<
<
Vo1
Vo2
Vo1
Vo2
<
<
<
<
5.23V
3.43V
3.48V
2.60V
0%
60mV pk-pk max.,
20mV rms max.
Outputs track
start-up and shutdown
Radiated emissions
Immunity:
ESD air
ESD contact
Radiated field enclosure
Conducted (DC power)
Conducted (signal)
Input transients
Input voltage range
48Vin nominal
Input current
No load
Remote OFF
UVLO turn ON voltage
UVLO turn OFF voltage
33 to 75VDC
60mA max.
20mA max.
33V (typ)
30V (typ)
Nominal line
Active high remote ON/OFF
Logic compatibility
ON
OFF
Level A
Level B
Level B
EN61000-4-2
8kV (NP), 15kV (RP)
EN61000-4-2
6kV (NP), 8kV (RP)
EN61000-4-3
10V/m (NP)
EN61000-4-6
10V (NP)
EN61000-4-6
10V (NP)
ETS 300 132-2, ETR 283
Efficiency
Operational insulation
See table
Input/output
Input/baseplate
1500VDC
1500VDC
Input fuse
5.0A slow blow
Fixed
400kHz (5V/3V3)
325kHz (3V3/2V5)
Approvals and standards
(See Notes 2 and 3)
UL/cUL1950, EN60950
TÜV Rheinland
Weight
MTBF
8ms (typ)
(See Note 4)
Open Collector ref. to -input
Open circuit or >4VDC
<1.2VDC
EN55022 with external filter
EN55022 with external filter
EN55022
GENERAL SPECIFICATIONS
Switching frequency
INPUT SPECIFICATIONS
Start-up time
ETS 300 386-1 table 5
Conducted emissions
45g (1.6 oz)
Telcordia SR-332
@ 25°C, 100% load
ground benign
3,080,891 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating baseplate
temperature
Non-operating
-40°C to +100°C
-40°C to +125°C
File Name: EXQ60D.PDF Rev: 19 Dec 2003