RP/RPT
Main Feature
1. 1 and 2-Poles version available with high switching
current up to 25A.
2. Plug-in Terminal with Flanged Case is available for
customer’s various applications.
3. Both AC and DC coil available.
4. LED version available.
Contact Rating
Load Type
RP-2P
RP-3P
20A/15VDC
20A/15VDC
10A 240VAC
10A 240VAC
13A/28VDC
13A/28VDC
13A 120VAC
13A 120VAC
30A/240VAC
25A/120VAC
20A/120VAC
13A 28VDC
13A 28VDC
10A/600VAC
25A/240VAC
15A/240VAC
-
-
-
Rated Carrying Current
RPT- 3P
30A/120VAC
Contact Capacity
RPT-2P
30A/28VDC
Rated Load (Resistive)
RPT (No Common)
5A/600VAC
-
-
-
1HP/120VAC
3/4HP/120VAC
1/2HP/120VAC
1/2HP 240VAC 1/2HP 240VAC
1 HP/200~600VAC 1HP/240/480/600VAC 1/2HP/208/240VAC 1/3HP 120VAC 1/3HP 120VAC
30A
25A
20A
13A
13A
AC 600V
AC 600V
AC 300V
AC 300V
AC 300V
DC 28V
DC 28V
DC 28V
DC 48V
DC 48V
Max. Allowable Current
30A
25A
20A
13A
13A
Max. Allowable Power
Force
7,200VA
6,000VA
3,600VA
2,400VA
2,400VA
840W
364W
364W
364W
364W
Max. Allowable Voltage
Contact Material
Ag Alloy
Ag Alloy
Ag Alloy
Ag Alloy
Ag Alloy
Contact Form
SPST, SPDT
DPST, DPDT
3PST, 3PDT
DPST, DPDT
3PST, 3PDT
Application
Vending Machine, Cooking Appliances, Office Machine,
Domestic Appliances, Control Equipment, etc
Performance (at Initial Value)
Contact Resistance ............. 100 mΩ Max.@1A,6VDC
Operate Time....................... 15 mSec. Max.
Release Time ...................... 10 mSec. Max.
Dielectric Strength:
Between Coil & Contact....... 1,500VAC at 50/60 Hz
for one minute
Between Contacts ............... 1,000VAC at 50/60 Hz
for one minute
Surge Strength..................... 1,500V (between Coil
& Contact 1.2x50µSec.)
Insulation Resistance .......... 100 MegaΩ Min. at
500VDC
Max. On/Off Switching:
Electrical .............................. 6 Cycles per Minute
Mechanical .......................... 300 Cycles per Minute
Temperature Range............. -45~+70°C
Humidity Range ................... 45~85% RH.
Coil Temperature Rise......... 50°C Max.
Vibration:
Endurance ...........................10 to 55 Hz dual
amplitude width 1.5mm
Error Operation ....................10 to 55 Hz dual
amplitude width 1.5mm
Shock:
2
Endurance ..........................1,000 m/S
2
Error Operation ....................100 m/S
Life Expectancy:
7
Mechanical...........................10 Operations at No
Load condition
5
Electrical ..............................10 Operations at Rated
Resistive Load
Weight..................................About 85 g
Accessories & Sockets
PPF-11A/AE.........................See Page 178
Safety Standard & File Number
RPT
UL & C-UL............................E175730
RP
NIL.