MXB-SERIES
Ⅵ Features
(1) Wide band, High attenuation by 2-stage choke
coil
(2) Block terminal with cover
Simple wire connection
High safety by cover.
MXB-1220-33
MXB-1230-33
Ⅵ Safety standard
UL1283,
CSA Std. C22. 2 No.8
VDE0565 Teil. 3, Teil 3A2
VDE0565 will transfer to EN133200
on and after July 23, 2003.
(
)
MXB-1206-33
MXB-1210-33
Ⅵ Specifications
Model
Item
MXB-1206-33
MXB-1210-33
MXB-1220-33
MXB-1230-33
20A (Note 2)
30A (Note 2)
250V
1
Rated voltage (AC, DC)
2
Rated current (AC, DC)
3
Test voltage (terminal to case, AC 1 minute)
2500V (25°C, 70% RH)
4
Isolation resistance (terminal to case, 500VDC)
100MΩ min. (25°C, 70% RH)
5
Leakage current
6A (Note 1)
10A (Note 1)
0.5mA max.
125V, 60Hz
1mA max.
250V, 60Hz
DC resistance
7
Temperature rise
8
Operating temperature range
9
Operating humidity
10
Storage temperature
11
Noise Filter
6
Storage humidity
12
Vibration
13
Safety standard
14
Weight (typ)
0.3Ω max.
0.1Ω max.
0.02Ω max.
35°C max.
0.01Ω max.
40°C max
–25 ~ +85°C
30% ~ 90% RH (No dewdrop)
–30 ~ +85°C
10% ~ 95% RH (No dewdrop)
Sweep: 10 ~ 55 ~ 10Hz (for 1 minute), Amplitude: 1.5mm X, Y and Z axes for 2 hours
Approved by UL1283, CSA C22.2 No. 8 (C-UL) and VDE0565 Teil3, Teil3A2
220g
310g
530g
660g
(Note 1) : Value at Ta < 50°C. Refer to the derating curve shown below at Ta > 50°C.
=
(Note 2) : Value at Ta < 45°C. Refer to the derating curve shown below at Ta > 45°C.
=
Ⅵ Circuit
Ⅵ Derating
ⅷ Request customer specification for further details of specifications, outline, characteristics, etc.
Read the instruction manual before usage.
ⅷ Contact us about delivery before ordering.
148