www.martekpower.com
HB30S
30 Watts Output Power
SINGLE
OUTPUT
FEATURES
FEATURES
How to Order
HB 30
S
SELECTION CHART
CHART
M / 5 - F
Series
Total Output
Power
Single Output
Unscreened (I) or Screened (M)
Output Voltage: Maximum current as stated
in selection chart
Options
Options:
F - Flange
S - Stud
INPUT CHARACTERISTICS
CHARACTERISTICS
Min.
Typ.
Max.
Units
16
28
40
Vdc
Input Voltage
12
14
Vdc
Brown Out (75% of Full Load) [fig. I]*
150
µA
Logic Disable Current (Sink)
0
0.8
Vdc
Logic Disable Voltage (TTL)
300
500
mw
Logic Disable Power In
Efficiency up to: See Page 29 [fig. II, III]*
86
%
>=5 Vdc Output (FL)
81
%
3.3 Vdc Output (FL)
73
%
2Vdc Output (FL)
EMI:
Units conform to MIL
-STD-461E
Input Transient: Units can withstand 50V transients for up to 100 ms
per MIL
-STD-704E
STABILITY
60 dB
Internal EMI Filter
SMD footprint
Remote Turn On
Remote Sense
Output Overvoltage Protection
Output Overcurrent Protection
Over Temperature Protection
100% Environmental Screening (M Models)
•
•
•
•
•
•
•
•
180°
Gain
Phase
0 dB
Nominal
Output Voltage
(Volts)
2
3.3
5
5.2
9
12
15
24
28
Output
Current
(Amps)
6.0
6.0
6.0
5.8
3.3
2.5
2.0
1.3
1.1
Model
Number
(Unscreened)
HB30SI/2
HB30SI/3.3
HB30SI/5
HB30SI/5.2
HB30SI/9
HB30SI/12
HB30SI/15
HB30SI/24
HB30SI/28
Model
Number
(Screened)
HB30SM/2
HB30SM/3.3
HB30SM/5
HB30SM/5.2
HB30SM/9
HB30SM/12
HB30SM/15
HB30SM/24
HB30SM/28
OUTPUT CHARACTERISTICS
CHARACTERISTICS
Min.
Typ.
Max.
Set Point Accuracy
50 1
Load Regulation
25 2
Line Regulation
25 3
Ripple P - P (10 MHz) [fig. IV]*
100 4
Overvoltage Protection
125
Transient Response Time/Overshoot [fig. V & VI]*
20 -80% Load (@Nom.Line)
100/100 500/250 5
Low Line - High Line (@FL)
100/100 500/250 5
50 -100% Load (@Nom.Line)
100/100 500/250 5
Temperature Drift
0.05
Current Limit
105
150
Short Circuit Current
25
50
75
Turn On Time [fig. XI]*
5
Logic Turn On Time [fig. IX]*
2.5
Units
mV
mV
mV
mV
% Vout
µS/mV
µS/mV
µS/mV
%/°C
% Iout
% Iout
mS
mS
0°
or 1 % maximum, whichever is greater
or 0.2% maximum, whichever is greater from no load to full load
3
or 0.2% maximum, whichever is greater from low line to high line
4
or 1 % maximum, whichever is greater
5
or 5 % maximum, whichever is greater
* see figures on page 29
1
2
-180°
-60 dB
100Hz
1KHz
10KHz
FREQUENCY
100KHz
>> 8
1111 Knox Street
Torrance
CA 90502
USA
Tel: +1 310 202 8820
sales@martekpower.com