DSEI120-06A
Fast Recovery
Epitaxial Diode (FRED)
VRSM
VRRM
V
600
Type
A
C
TO-247 AD
V
600
IFAVM = 126 A
VRRM = 600 V
trr = 35 ns
DSEI 120-06A
C
A
C
A = Anode, C = Cathode
Symbol
Conditions
Maximum Ratings
IFRMS
IFAVM
IFAV
IFRM
TVJ = TVJM
TC = 70°C; rectangular, d = 0.5
TC = 110°C; rectangular, d = 0.5
tP < 10 µs; rep. rating, pulse width limited by TVJM
IFSM
TVJ = 45°C;
A
A
A
A
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
600
660
A
A
TVJ = 150°C; t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
540
600
A
A
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
1800
1800
A2s
A2s
TVJ = 150°C; t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
I2t
100
126
77
1200
1450
1500
A2s
A2s
-40...+150
150
-40...+150
°C
°C
°C
357
W
0.8...1.2
Nm
6
g
TVJ = 45°C;
TVJ
TVJM
Tstg
Ptot
TC = 25°C
Md
mounting torque
Weight
typical
Symbol
Conditions
Characteristic Values
typ.
max.
IR
VR = VRRM
VR = 0.8·VRRM
VR = 0.8·VRRM
TVJ = 25°C
TVJ = 25°C
TVJ = 125°C
3
0.75
20
mA
mA
mA
VF
IF = 70 A
TVJ = 150°C
TVJ = 25°C
1.12
1.3
V
V
VT0
rT
for power-loss calculations only
TVJ = TVJM
0.85
3.5
0.35
(version A)
35
IF = 1 A; -di/dt = 200 A/µs; VR = 30 V; TVJ = 25°C
35
50
VR = 350 V; IF = 80 A; -diF/dt = 200 A/µs
L < 0.05 µH; TVJ = 100°C
17
21
• Antiparallel diode for high frequency
switching devices
• Anti saturation diode
• Snubber diode
• Free wheeling diode in converters
and motor control circuits
• Rectifiers in switch mode power
supplies (SMPS)
• Inductive heating and melting
• Uninterruptible power supplies (UPS)
• Ultrasonic cleaners and welders
Advantages
• High reliability circuit operation
• Low voltage peaks for reduced
protection circuits
• Low noise switching
• Low losses
• Operating at lower temperature or
space saving by reduced cooling
ns
IRM
Applications
K/W
K/W
K/W
trr
• International standard package
JEDEC TO-247 AD
• Planar passivated chips
• Very short recovery time
• Extremely low switching losses
• Low IRM-values
• Soft recovery behaviour
• Epoxy meets UL 94V-0
V
mW
RthJC
RthCH
RthJA
Features
A
Chip capability, limited to 70 A by leads
0.25
Data according to IEC 60747
IXYS reserves the right to change limits, test conditions and dimensions.
© 2012 IXYS All rights reserved
20121114a
1-3