Dimensions: [mm]
Recommended Land Pattern: [mm]
Electrical Properties:
Properties
Test conditions
Value
4,70
V
max.
V
±5%
VBR
70.2
Clamping Voltage
IPEAK
VClamp
96.8
V
max.
(Reverse) Peak Pulse Current
2,30
1 mA
10/1000 µs
IPeak
15.5
A
max.
IPeak
200
A
max.
3,30
(Forward) Peak Pulse Current 1)
Leakage Current
VDC
ILEAK
1
µA
max.
Steady State Power Dissipation
TA = 50 °C
PDISS
6.5
W
max.
Power Dissipation 2)
10/1000 µs
PDISS
1500
W
max.
Polarity
3,05 ± 0,15
7,94 ± 0,19
Tol.
60
(Reverse) Breakdown Voltage
9,30
1,14 ± 0,38
Unit
VDC
DC Operating Voltage
Unidirectional
1)
2)
8.3 ms single half-sine wave or equivalent square wave, Duty cycle = 4 pulses per minute
Mounted on 5.0 mm x 5.0 mm (0.03 mm thick) Copper Pads to each terminal
Scale - 4:1
6,86 ± 0,25
2,5 ± 0,3
2,34 ± 0,28
Schematic:
Cathode
General Information:
It is recommeded that the temperature of the component does not exceed +150°C under worst
case conditions
-65 °C up to +150 °C
Storage Temperature (in original
packaging)
5,9 ± 0,32
Operating Temperature
-40 °C up to +60 °C
Test conditions of Electrical Properties: +20°C, 33% RH if not specified differently
Cathode Band
Anode
Scale - 4:1
Product Marking:
Marking
GGK
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
CREATED
CHECKED
GENERAL TOLERANCE
KaS
RoD
DIN ISO 2768-1m
PROJECTION
METHOD
DESCRIPTION
WE-TVSP Power TVS Diode
ORDER CODE
www.we-online.com
eiSos@we-online.com
824540601
SIZE
REVISION
STATUS
DATE
BUSINESS UNIT
PAGE
DO-214AB
001.000
Draft
2015-11-10
eiSos
1/7
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.