ト
PAF SERIES
DC/DC Module 400W-700W
2
ks
PAF
warranty
医 療
計 測
F A
医 療 半導体
計 測 その他
F A
半導体
その他
■ Features
ph
コンピュータ
通 信
pf-a
コンピュータ
Y
E
A
R
S
通 信
hk-a
hws
コンピュータ
● Full brick F A
通 信
industry standard size 半導体
(61×12.7×116.8mm)
半導体
F A
● High power density (industry-leading level in PAF700
F48)
● road range of baseplate operating temperatures: -40
B
to +100C (-20 to +85℃ for PAF400F280)
● igh efficiency: 91% max (PAF700F48/PAF450F280/
H
F A
コンピュータ
通 信
F A
半導体
PAF600F280) 半導体
● arge output current applicable to low voltage model:
L
100A (PAF400F280-1.8/3.3)
● ide variety of functions
W
Remote sensing (+S/-S), ON/OFF control (CNT), Output voltage trimming (TRM), Inverter operation monitoring (IOG), Parallel control (PC), Auxiliary power supply
(AUX), Over voltage protection (OVP), Over current
protection (OCP)
● Internal capacitor: Ceramic capacitor only (high reliability)
コンピュータ
■ Applications
通 信 コンピュータ
医 療
計 測
通 信
F A
医 療
半導体
計 測
F A
半導体
フォーマット
■ Model naming method
PAF 500 F 48 − 12 / □
Option
Blank: Standard
T: Through hole type
Nominal output voltage
Nominal input voltage
Function
F: Full function
Output power
400, 450, 500, 600, 700〔W〕
Series name
■ Conformity to RoHS Directive
This means that, in conformity with EU Directive 2002/95/
EC, lead, cadmium, mercury, hexavalent chromium, and
specific bromine-based flame retardants, PBB and PBDE,
have not been used, except for exempted applications.
■ Product Line up
alpha
コンピュータ
通 信
dlp
コンピュータ
通 信
fps
コンピュータ
通 信
PAF-F24(DC24Vin)
PAF-F48(DC48Vin)
500W
600W
500W
600W
700W
Output
Voltage Output Current
Model
Output Current
Model
Output Current
Model
Output Current
Model
Output Current
Model
医 療
計 測
F A
コンピュータ
通 信
医 療
計 測
F A
半導体
3.3V
−
−半導体
−
−
80A
PAF500F48-3.3
−
−
−
−
5V
−
−
−
−
80A
PAF500F48-5
−
−
−
−
12V
42A
PAF500F24-12
50A
PAF600F24-12
42A
PAF500F48-12
50A
PAF600F48-12 58.5A PAF700F48-12
28V
18A
PAF500F24-28 21.5A PAF600F24-28
18A
PAF500F48-28 21.5A PAF600F48-28
25A
PAF700F48-28
医 療
計 測
F A
コンピュータ
通 信
医 療
PAF-F280(DC280Vin)
半導体
計 測
F A
半導体
400W
450W
Output
Voltage Output Current
Model
Output Current
Model
Output Current
1.8V
100A PAF400F280-1.8
−
−
−
3.3V
100A PAF400F280-3.3
−
−
−
5V
80A
PAF400F280-5
−
−
−
医 療
計 測
F A
半導体
コンピュータ
通 信
医 療
計 測
F A
半導体
12V
−
−
38A PAF450F280-12 50A
24V
−
−
19A PAF450F280-24 25A
28V
−
−
16.5A PAF450F280-28 21.5A
48V
−
−
9.5A PAF450F280-48 12.5A
・All specifications are subject to change without notice.
600W
Model
−
−
−
PAF600F280-12
PAF600F280-24
PAF600F280-28
PAF600F280-48
Note) The pin configuration differs depending on
the product. Refer to the appearance diagram for detail.
B-93
PAF600F24
PAF600F24 Specifications
MODEL
200
PAF600F24-28
DC19 - 36
(*1)
(*2)
89
28.9
12
50
600
28
21.5
602
±1
24
24
56
56
0.02%/℃
280
-40%, +10%
105% - 140%
115% - 135%
Possible
Possible (SHORT: ON OPEN: OFF)
Possible
Possible
Possible (Open collector output)
-40 to +100 (Baseplate) Ambient Temperature min=-40
-40 to +100
30 - 95 (No dewdrop)
10 - 95 (No dewdrop)
PAF
At no operating, 10-55Hz (sweep for 1min.)
Amplitude 0.825mm constant (maximum 49.0m/s²) X, Y, Z 1 Hour each
Shock
Cooling
Isolation
DC20 - 36
(*10) mVp-p
(*10)
(*5)
(*6)
(*9)
(*9)
(*9)
(*9)
(*9)
(*7) ℃
℃
%RH
%RH
Voltage Range
Efficiency (typ)
Current (typ)
Nominal Voltage
Maximum Current
Maximum Power
Voltage Setting Accuracy
Output Maximum Line Regulation
Maximum Load Regulation
Temperature Coefficient
Maximum Ripple & Noise
Voltage Adjustable Range
Over Current Protection
Over Voltage Protection
Remote Sensing
Function Remote ON/OFF Control
Parallel Operation
Series Operation
I.O.G. Signal
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Environment
Vibration
Input
PAF600F24-12
V
%
A
VDC
A
W
(*2) %
(*3) mV
(*4) mV
ITEMS/UNITS
196.1m/s²
Conduction cooled
(*8)
Input-Baseplate : 1.5kVDC, Input-Output : 1.5kVDC for 1min.
Output-Baseplate : 500VDC for 1min.
Withstand Voltage
Isolation Resistance
More than 100MΩ at 25℃ and 70%RH Output-Baseplate...500VDC
Standards Safety Standards
Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1
Weight (typ)
Mechanical
Size (W x H x D)
g
mm
250
61 x 12.7 x 116.8 (Refer to outline drawing)
(*1) At 24VDC, 80% of maximum output current and baseplate temperature = +25℃.
(*2) At 24VDC and maximum output current.
(*3) 20 - 36VDC, constant load. (PAF600F24-12)
19 - 36VDC, constant load. (PAF600F24-28)
(*6) Inverter shutdown method, manual reset.
(*7) Ratings - Refer to derating curve below.
- Load(%) is percent of maximum output current.
(*8) Heatsink has to be chosen according to instruction manual.
(*9) Refer to instruction manual.
(*4) No load - full load, constant input voltage.
(*10) External components are needed for operation.
(Refer to basic connection and instruction manual.)
(*5) Constant current limiting with automatic recovery.
Output Derating
100%
Load
(%)
83%
80%
60%
40%
20&
●Outline Drawing Basic Connection
・
0%
-40
-20
0
20
40
60
80 85
Baseplate Temperature
(℃)
・All specifications are subject to change without notice.
GO!!
B-99Page
100
B-95