VDE
HIGH ELECTRICAL &
MECHANICAL NOISE
IMMUNITY RELAY
FEATURES
10
.394
20
.787
JQ-RELAYS
• High electrical noise immunity
• High switching capacity in a compact package
• High sensitivity: 200 mW (1a), 400 mW (1c)
• High surge voltage: 8,000 V between contacts and coil
• VDE, TÜV, SEMKO also approved
15.6
.614
mm inch
SPECIFICATIONS
Contact
Characteristics
Standard type
High capacity type
1 Form A, 1 Form C
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
100 mΩ
Silver alloy
5 A 125 V AC
10 A 125 V AC
1a
2 A 250 V AC
5 A 250 V AC
5 A 30 V DC
5 A 30 V DC
Nominal
5 A 125 V AC
10 A 125 V AC
N.O.
2 A 250 V AC
5 A 250 V AC
switching
3 A 30 V AC
5 A 30 V DC
capacity
1c
2 A 125 V AC
3 A 125 V AC
Rating
N.C.
1 A 250 V AC
2 A 250 V AC
(resistive)
1 A 30 V DC
1 A 30 V DC
1a
625 VA, 150 W
1,250 VA, 150 W
Max.
switching
N.O.
625 VA, 90 W
1,250 V AC, 150 W
1c
power
N.C.
250 VA, 30 W
500 V AC, 30 W
Max. switching voltage
250 V AC, 110 V DC (0.3A)
Max. switching current N.O.: 5 A N.C.: 2 A N.O.: 10 A N.C.: 3 A
Expected mechanical life
107
(at 180 cpm)(min. operations)
1a
Standard type
N.O.
1c
N.C.
1a
High capacity
type
N.O.
1c
N.C.
Initial
Between open contacts
breakdown
voltage*2
Between contacts and coil
Surge voltage between
contact and coil*3
Operate time*4 (at nominal voltage)
Release time*4
(at nominal voltage)(without diode)
Temperature rise*5
Functional*6
Shock
resistance Destructive*7
Vibration
resistance
Functional*8
Destructive
Conditions for operation,
Ambient
transport and storage*9
temp.
(Not freezing and condensHumidity
ing at low temperature)
Unit weight
Expected electrical life (min. operations)
Type
Max. operating speed
Initial insulation resistance*1
Switching capacity
5 A 125 V AC
3 A 125 V AC
2 A 250 V AC
5 A 30 V DC
5 A 125 V AC
2 A 250 V AC
3 A 30 V DC
No. of operations
5×104
2×105
2×105
105
5×104
2×105
105
2 A 125 V AC
1 A 250 V AC
1 A 30 V DC
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
2×105
2×105
105
5×104
5×104
105
5×104
5×104
105
3 A 125 V AC
2 A 250 V AC
1 A 30 V DC
8,000 V
Approx. 5 ms
Approx. 2 ms
Max. 45°C
Min. 294 m/s2 {30 G}
Min. 980 m/s2 {100 G}
98 m/s2 {10 G}, 10 to 55 Hz
at double amplitude of 1.6 mm
117.6 m/s2 {12 G}, 10 to 55 Hz
at double amplitude of 2.0 mm
–40°C to +70°C
–40°F to +158°F
5 to 85% R.H.
Approx. 7 g .25 oz
Remarks
2×105
2×105
105
1a: 200 mW
20 cpm
Min. 1,000 MΩ at 500 V DC
1a: 1,000 Vrms for 1 min.
1c: 750 Vrms for 1 min.
4,000 Vrms for 1 min.
1c: 400 mW
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section
*2 Detection current: 10 mA
*3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981
*4 Excluding contact bounce time
*5 Measured conditions
Standard type
High capacity type
Resistive, nominal voltage applied to the coil.
Contact carrying current: 5 A, at 70°C 158°F
Resistive, nominal voltage applied to the coil.
Contact carrying current: 10 A, at 70°C 158°F
*6 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*7 Half-wave pulse of sine wave: 6ms
*8 Detection time: 10µs
*9 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
Coil (at 20°C 68°F)
Nominal operating power
79