Power Line Filters
Single Stage Wire Leads
62-PML Series
Tested and found to be
IAW VDE 0565 Part 3
Features
s
s
s
s
s
s
s
Compact design requires minimal real estate space
Suitable for products that must conform
to FCC and FTZ regulations
Excellent attenuation for high voltage impulse
Metal case provides effective shielding
Excellent filtering characteristics for both normal mode
and common mode
Structure provides effective shielding for noise
generated externally and internally
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 65)
Circuit Diagram
1
3
CY
L1
CX
CX
R
Applications
Power Line Filters
s
s
s
s
s
E
Digital equipment
Personal computers and peripherals
Measuring instruments
Medical equipment
Factory automation equipment
CY
4
2
Specifications
Model
Rated Voltage
(@ 50/60Hz)
62-PML-030-3-11
62-PML-030-5-11
62-PML-050-3-11
62-PML-050-5-11
62-PML-100-5-11
3A
250VAC
5A
10A
CY
0.35mA
2200pF
3300pF
0.35mA
2200pF
0.50mA
1.5A
62-PML-015-5-11
Leakage Current
(Max.)
0.50mA
62-PML-015-3-11
Rated
Current
Capacitance
3300pF
0.35mA
2200pF
0.50mA
3300pF
0.50mA
3300pF
CX
Inductance
(L1)
Temperature
Rise (Max.)
10.0mH
4.3mH
30°C
0.1uF
2.4mH
2.2mH
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 62-PML-015 Series: 3.06 ounces (87 grams)
62-PML-030 Series: 3.17 ounces (90 grams)
62-PML-050 Series: 3.28 ounces (93 grams)
Discharge time: 0.4 sec. max.
64
SPECTRUM CONTROL INC. • 8031 Avonia Rd. • Fairview, PA 16415 • Phone: 814-474-2207 • Fax: 814-474-2208 • Web site: www.spectrumcontrol.com
SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58