VSB/VSC/VSP Series
10W to 150W Single Output, 115VAC Input
Features
u Input transient protected
u 2 year warranty
u High quality design
u 200% Peak Power Version (VSP)
u Broad product range
Key Market Segments & Applications
Specifications
VS10C
Model
AC Input Voltage range
DC Input Voltage range
VDC
Inrush Current (100VAC)
(1)
A
Temperature Coefficient
Overcurrent Protection
(2)
Overvoltage Protection
V
Hold Up Time (Typ) at 100VAC
ms
Remote Sense
Operating Temperature
(3)
Storage Temperature
Humidity (non condensing)
Cooling
(4)
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated EMI
Recommended EMI Filter
Weight (Typ) (VSP)
Size (WxHxD)
Warranty
g
mm
yrs
VS15C
VS30C
VS50B
VS75B
VS100B
VS150B
VS50P
VS75P
VS100P
VS150P
85-132VAC (47-440Hz)
110 - 175VDC
25
30
25
30
30
20
20
<0.02%/ºC
~105%
VSB:~125%; VSP: >102% of Peak
~115% Diode Clamp
~115 - 135% Manual Reset
20
17
None
-10ºC to +60ºC, derate linearly to 70% load from 50ºC to 60ºC
-30 to +85ºC
Storage 10-95% RH, Operating 30-90% RH
Convection
Forced
Input to Ground 2kVAC (20mA), Input to Output 2kVAC (20mA),
Output to Ground 500VAC (100mA) for 1 min.
>100M at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
< 196.1 m/s2
UL60950-1, CSA60950-1, EN60950-1
FCC Class B, VCCI-B
RSEL-20R5W
RSEL-2001W
RSEL-2002W RSEL-2003W
RSEL-2006W
65
80
150
200
350 (280) 420 (350)
550 (480)
See Outline Drawings
Two Years
Notes:
(1) 25°C ambient (cold start)
(2) Avoid prolonged operartion in overload
(3) VS50B24 -10°C to +60°C, derate linearly to 62% load from 40°C to 60°C, VS50P derate to 60% at 60°C
(4) 0.7m/s forced air required, consult installation manual for derating with convection cooling
1-800-526-2324 • www.us.tdk-lambda.com/lp/
142
Disclaimer: us.tdk-lambda.com/lp/legal.htm