S2(UL) Series
UL Approved* Axial Style Reed Relay
Variable mounting options
10W, 50W and 100VA contact options
Reliable reed switch contacts
Contact Specification
Conditions
Units
S2-03P
Switch atmosphere
S2-XXP
S2-XXE
Ruthenium
Material
Rhodium
Rhodium
Pressurised
Pressurised
Vacuum
Volts DC
Isolation across contacts
200
500
1000
Switching power max.
The relay can be mounted in a variety of
methods and orientations to suit particular
applications. The leadout wires are
flexible enough to allow bending for
assembly into equipment.
Watts
10
50
-
Switching power max.
The S2(UL) reed relay series from Cynergy3
has been developed and approved by UL
for applications where PCB mounting is
not possible.
Resistive load
Resistive load
VA
-
70
100
Switching voltage DC max.
Resistive load
Volts DC
200
350
350
Switching voltage AC max.
Resistive load
Volts AC RMS
140
300
300
Switching current DC max.
Resistive load
mA DC
250
700
1000
Switching current AC max.
Resistive load
mA AC RMS
250
500
1000
Amps DC/AC
RMS
1
2.5
2.5
Carry current max.
Contact capacitance max.
Open
Pico Farad (pF)
0.3
0.5
0.5
Initial contact resistance
max.
@Nominal
coil voltage
Milliohms (mΩ)
100
100
100
Ohms (Ω)
10E10
10E10
10E10
Operations 50%
duty cycle
Operations 50%
duty cycle
10E7
(12V DC, 4mA)
10E6
(350V DC, 1mA)
10E7
(500V DC, 1mA)
Insulation resistance
Hot switching
resistive load
Life time operations
Available with either a 10W or 50W contact
in a pressurised reed switch or a 100VA
contact in an evacuated reed switch.
Please refer to this document for circuit
design notes:http://www.cynergy3.com/blog/application
-notes-reed-relays-0
Dry switching
Coil Specification
Must operate voltage
Must release voltage
Operate time inc bounce
Release time inc bounce
Resistance
@20°C
@20°C
@20°C
@20°C
@20°C
Relay Specification
Isolation contact /coil min.
Operating temp range
Storage temp range
*Consult factory for UL ratings
Standard Parts
S2-03PU
S2-05PU
S2-12PU
S2-24PU
S2-05EU
S2-12EU
S2-24EU
10E9
3V
2.25
0.5
0.1
0.07
250
Volts DC
Volts DC
Milliseconds
Milliseconds
Ohms
5V
3.7
1
1.0
0.5
160
Volts DC
500V DC, 60
sec, 20°C
±5°C, 45% Rh
Insulation resistance
contact to coil
10E8
Coil Volts VDC
3
5
12
24
5
12
24
T.B.C.
°C
°C
24V
19
3
11
0.5
1000
1000
Ohms
12V
9
2
1
0.5
1000
-40 to +85
-40 to +125
Switching Power
10W
70VA
70VA
70VA
100VA
100VA
100VA
Isolation VDC
200
500
500
500
1000
1000
1000
Switch Atmosphere
Pressurised
Pressurised
Pressurised
Pressurised
Vacuum
Vacuum
Vacuum
Custom versions can be made for particular applications. Please contact Cynergy3 with your requirements.
Mechanical Dimensions
2.0
4.0
Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate
Wimborne, Dorset BH21 7PE
Telephone +44 (0) 1202 897969
Email:sales@cynergy3.com
ISO9001 C E R T I F I E D
www.cynergy3.com
S2(UL) Series 2016
© 2016 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.