(1/2)
EMC Filters for AC Power Line
Inlet-socket Type ZUG-13AS Series
FEATURES
• This inlet-socket type EMC filter prevent microcomputer operational errors by use of a common mode choke coil featuring an
amorphous core with exceptional magnetic characteristics.
• Sharply attenuates high voltage pulses entering from the power
supply line. For example, the ZUG2203-13AS achieves over
20dB of attenuation for a 600V, 400ns input pulse.
• Lug type output terminals for soldering.
• Compact and low-cost due to use of an insulating plastic case.
• It is a product conforming to RoHS directive.
Conformity to RoHS Directive
SAFETY STANDARDS
Standard and standard No.
U.S.A.
Canada
Part No.
ZUG2203-13AS
ZUG2206-13AS
Europe
CSA
UL
UL1283
E62388
E62388
NEMKO
CSA C22.2 No.8
LR76849C
LR76849C
EN60939
P08208996
P08208996
APPLICATIONS
Personal computers, computer terminals, various types of office
automation equipment, digital devices(ECRs, electronic calculators, electronic scales, etc.), measurement equipment, medical
equipment, etc. Particularly appropriate for various types of electronic devices that require miniaturization.
SHAPES AND DIMENSIONS
Typical dimensions for installation
C
F
J
40
30
40
31.2
øH
From front panel
ø3.6 or M3 tap
R1
Ground
terminal
A
D
I
G
From back side panel
ø3.6
R5.5
E
B
23.2
11
20
• Tighten the panel mounting M3 dia. bolt with the torque under 5.88x10-1N • m.
Dimensions in mm
Part No.
A
B
C
D
ZUG2203-13AS, 2206-13AS
50
40.2
22.5
40
• Case:plastic, input terminal:inlet-socket(EN60320), output terminal: lug terminal
E
35
F
5.2
G
30.5
øH
3.3
I
20
J
8
ELECTRICAL CHARACTERISTICS
Part No.
Rated voltage Eac (V)
Rated current (A)
Test voltage Eac (V)[Between terminal and ground terminal]
Insulation resistance (MΩ)[DC.500V,1min/between terminal and ground terminal]
Leakage current (mA) [250V • 60Hz]
DC resistance(mΩ)
Operating temperature range(° C)[Including self-temperature rise]
With derating over(°C)
Temperature rise(° C)
Differential mode 30dB
Attenuation frequency range
(MHz)[+5 to +35° C]
Common mode 30dB
Differential mode
Pulse attenuation characteristics
Input pulse voltage (kV)∗
Common mode
Weight (g)
∗ Input
ZUG2203-13AS
250
3
1500
100min.
0.5max.
150max.
–25 to +85
55
30max.
4 to 30
3 to 30
0.6[10dB]
0.6[20dB]
33
ZUG2206-13AS
250
6
1500
100min.
0.5max.
100max.
–25 to +85
55
30max.
5 to 30
5 to 30
0.3[10dB]
0.4[10dB]
33
pulse width:0.4µs
• Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific
bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications.
• All specifications are subject to change without notice.
003-01 / 20080818 / e9164_zug_13as.fm