Ordering information
AC-DC Power Supplies Enclosed type
PBA600F
PBA/PBW
PBA/PBW
PB
1
A
2
600
3
F
4
Recommended EMI/EMC Filter
NAC-16-472
R
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
-5
5
-O
6
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional *6
C :with Coating
G :Low leakage current
U :Operation stop voltage
is set at a lower value
F1 :With Long-Life fan
F3 :Reverse air exhaust
type
F4 :Low speed fan
Refer to instruction manual
7.1.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA600F-3R3
396
ACIN 100V 3.3V 120A
ACIN 200V *3 3.3V 120A
PBA600F-5
600
5V 120A
5V 120A
PBA600F-7R5
600
7.5V 80A
7.5V 80A
PBA600F-12
636
12V 53A
12V 53A
PBA600F-15
645
15V 43A
15V 43A
PBA600F-24
648
24V 27A
24V 27(31)A
PBA600F-36
648
36V 18A
36V 18A
PBA600F-48
624
48V 13A
48V 13A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 100V
ACIN 200V
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
ACIN 100V
CURRENT[A]
ACIN 200V *3
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C *1
RIPPLE[mVp-p]
-20 - 0C *1
0 to +50C *1
RIPPLE NOISE[mVp-p]
-20 - 0C *1
0 to +50C
TEMPERATURE REGULATION[mV]
-20 to +50C
DRIFT[mV]
*2
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V] *4
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT -RC
INPUT-FG
OUTPUT-RC-AUX-FG
OUTPUT-RC -AUX
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS (At only AC input)
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
PBA600F-3R3 PBA600F-5
PBA600F-7R5 PBA600F-12
PBA600F-15
PBA600F-24
PBA600F-36
AC85 - 264 1f or DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *5)
5.8typ
8.2typ
3typ
4.1typ
50/60 (47 - 63)
70typ
75typ
76typ
79typ
79typ
81typ
82typ
72typ
77typ
79typ
82typ
82typ
84typ
84typ
0.98typ (Io=100%)
0.95typ (Io=100%)
20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)
40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)
0.45/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1, DENAN)
3.3
5
7.5
12
15
24
36
120
120
80
53
43
27
18
120
120
80
53
43
27(31)
18
20max
20max
36max
48max
60max
96max
144max
40max
40max
60max
100max
120max
150max
150max
80max
80max
120max
120max
120max
120max
150max
140max
140max
160max
160max
160max
160max
160max
120max
120max
150max
150max
150max
150max
200max
160max
160max
180max
180max
180max
180max
240max
40max
50max
75max
120max
150max
240max
360max
60max
75max
120max
180max
180max
290max
440max
12max
20max
30max
48max
60max
96max
144max
400typ(ACIN 100/200V, Io=100%) *Start-up time is 500ms typ for less than 1minute of applying input again from turning off
20typ (ACIN 100/200V, Io=100%)
2.64 - 3.96
3.96 - 6.00
5.25 - 8.25
8.25 - 13.20
10.50 - 16.50 16.50 - 26.40 25.20 - 39.60
3.30 - 3.40
5.00 - 5.15
7.50 - 7.80
12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44
Works over 105% of rated current or 101% of peak current and recovers automatically
Vo+0.66 - 1.32 Vo+1.0 - 2.0
Vo+1.5 - 3.0
Vo+2.4 - 4.8
Vo+3.0 - 6.0
Vo+4.8 - 9.6
Vo+7.2 - 14.4
LED (Green)
Provided
Provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
-20 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 *7
120X61X190mm [4.72X2.4X7.48 inches] (without terminal block and screw) (W XHXD) /1.6kg max
Forced cooling (internal fan)
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.
*4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage
protection circuit is please contact us for details.
PBA/PBW-18
PBA/PBW-18
*5
*6
*7
*
Derating is required.Consult us for details.
Please contact us about safety approvals for the model with option.
Please contact us about class C.
A sound may occur from power supply at pulse loading.
PBA600F-48
81typ
83typ
48
13
13
192max
300max
150max
400max
200max
500max
480max
600max
192max
the input voltage.
38.40 - 56.00
48.00 - 49.92
Vo+4.8 - 12.0