Ordering information
DC-DC Converters PCB Mount type
ZTS1R5
ZT
1
S
2
1R5
3
12
4
DC OUTPUT
5
1Series name
2Single output
3Output wattage
4Input voltage
5Output voltage
R
MODEL
MAX OUTPUT WATTAGE[W]
05
ZTS1R50505
1.50
VOLTAGE[V] 5
CURRENT[A] 0.30
ZTS1R50512
1.56
12
0.13
ZTS1R50515
1.50
15
0.10
ZTS1R51205
1.50
5
0.30
ZTS1R51212
1.56
12
0.13
ZTS1R51215
1.50
15
0.10
ZTS1R52405
1.50
5
0.30
ZTS1R52412
1.56
12
0.13
ZTS1R52415
1.50
15
0.10
ZTS1R54805
1.50
5
0.30
ZTS1R54812
1.56
12
0.13
ZTS1R54815
1.50
15
0.10
ZTS1R52415 ZTS1R54805 ZTS1R54812
DC36 - 72
0.088typ 0.043typ 0.045typ
71typ
73typ
73typ
15
5
12
0.10
0.30
0.13
60max 20max 48max
120max 40max 100max
120max 80max 120max
150max 120max 150max
180max 50max 150max
60max 20max 48max
ZTS1R54815
SPECIFICATIONS
ZU/ZT
MODEL
VOLTAGE[V]
*1
CURRENT[A]
INPUT
*1
EFFICIENCY[%]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
*2
RIPPLE[mVp-p]
OUTPUT
RIPPLE NOISE[mVp-p] *2
TEMPERATURE REGULATION[mV] -20 to +55C
*3
DRIFT[mV]
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
PROTECTION
OVERCURRENT PROTECTION
CIRCUIT
INPUT-OUTPUT
ISOLATION INPUT-CASE
OUTPUT-CASE
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
IMPACT
SAFETY
AGENCY APPROVALS
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
*1
*2
*3
*
ZTS1R50505 ZTS1R50512 ZTS1R50515 ZTS1R51205 ZTS1R51212
DC4.5 - 9
DC9 - 18
0.441typ 0.459typ 0.441typ 0.176typ 0.183typ
68typ
68typ
68typ
71typ
71typ
5
12
15
5
12
0.30
0.13
0.10
0.30
0.13
20max 48max 60max 20max 48max
40max 100max 120max 40max 100max
80max 120max 120max 80max 120max
120max 150max 150max 120max 150max
50max 150max 180max 50max 150max
20max 48max 60max 20max 48max
20max (Minimum input, Io=100%)
ZTS1R51215 ZTS1R52405 ZTS1R52412
DC18 - 36
0.176typ 0.088typ 0.092typ
71typ
71typ
71typ
15
5
12
0.10
0.30
0.13
60max 20max 48max
120max 40max 100max
120max 80max 120max
150max 120max 150max
180max 50max 150max
60max 20max 48max
Fixed
4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75
Works over 105% of rating and recovers automatically
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
-20 to +71C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-40 to +85C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 98.0m/s2 (10G), 3minutes period, 60minutes each along X, Y and Z axis
490.3m/s2 (50G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL, EN60950-1 Complies with IEC60950-1
28X21X10mm (WXHXD) / 15g max
Convection
Rated input. 5V, 12V, 24V or 48V DC, Io=100%
Measured by 20MHz oscilloscope.
The drift is a change at 25C of ambient temperature and 30 minutes - 8 hours after the input voltage applied at rated input/output.
Series/Parallel operation with other model is not possible.
ZU/ZT-14
0.043typ
73typ
15
0.10
60max
120max
120max
150max
180max
60max